![Artel NCA115-2A Manual Download Page 30](http://html1.mh-extra.com/html/artel/nca115-2a/nca115-2a_manual_2977524030.webp)
30 of 36
EN
Maintenance and cleaning
All cleaning of all parts must be carried out with the pellet insert
completely cold and unplugged to avoid burns and thermal shock. The
pellet insert does not need much maintenance if used with certified
quality pellet. The need for maintenance varies depending on the conditions of use
(switching on and off repeatedly) and depending on the performance required.
◊ by the user
• by the authorised qualified technical assistance
Every 1200 hours of work the electronic board sends a warning signal and the
display will show “
S E R V I C E
S E R V I C E
”. This indicates the need for a thorough cleaning of the
pellet insert by a CAT. The lack of such cleaning could result in failure of the pellet
insert and poor combustion, thereby resulting in a lower yield.
Parts
Everyday
Every 2-3
days
Every week
Every 15
days
Every 30
days
Every 60-
90 days
Every year /
1200-1400 h
Brazier
◊
Pulizia raschiatore (ove
presente)
◊
Cleaning ash collection
compartment
◊
Cleaning ash tray
◊
Cleaning the door and
glass
◊
Cleaning the interior heat
exchanger /
smoke fan compartment
•
Cleaning complete
exchanger
•
Clean "T" to exhaust
•
Flue
•
Door gasket ash
•
Internal parts
•
Flue pipe
•
Electromechanical
components
•
Summary of Contents for NCA115-2A
Page 32: ...32 of 36 EN...