Stand-by Mode
This mode allows the automatic shutdown of the pellet insert once it reaches the temperature set on
SET.
When this happens, the pellet insert will wait a few minutes (factory setting), after which will turn off
automatically if the temperature of the room in the meantime has always maintained above the set.
Once turned off as a result of this condition, the pellet insert will automatically turn on only when the
ambient temperature will drop to 2 °C below the set temperature in the oven (example: SET=24 °C and
ambient temperature = 21 °C).
If the pellet insert is turned off for the sleep-mode, although there is an ignition programmed this will
be ignored and the heater will turn back on only to lower the temperature as explained above.
The sleep timer is instead always respected if the pellet insert is in STAND-BY and is turned off manually
by pressing the OFF button; doing so the pellet insert will shut down permanently rekindling not more,
less than expected from the ignition weekly programming.
Enabling stand-by mode
Press the SET (3) to access the menu and with the button
(5) reach the MENU 05 (“STAN-BY
MODE”). Then press SET (3) to access it; STAND-BY function is set by default to OFF. To activate
this feature, press
(1), on the display you will see “STAN-BY MODE ON”. Press SET (3) to con-
firm and then OFF (4) to leave. The STAND-BY mode is now active.
External thermostat
The pellet insert has the possibility to interface with an external thermostat for controlling the switching
on and switching off of the heater based on the room temperature. IThe thermostat must be of the
open / closed type with a clean contact.
If the thermostat carries voltage to the card causing faults, the warranty will expire.
To configure the thermostat, simply remove the jumper on the Therm clamp and connect the room
thermostat.
OPERATION BY A SPECIALIZED TECHNICIAN
Once switched on, the pellet insert will remain in operation until the temperature set in the thermostat
is reached.
When the contact is opened the pellet insert will remain in modulation and the display will show ECO
THERM for 5 minutes, after which it will go to Stand-by ECO + OFF.
At the moment of a new heat request in the room (and therefore re-closing of a contact), the pellet
insert will remain in ECO ATT mode for 10 minutes. If during this time the contact remains closed, the
pellet insert will switch on.
REMARKS:
At the moment when the pellet insert will be switched off manually or by programming, it will no longer
be connected by the thermostat.