It is recommended that emissions are checked after installation.
To obtain the test report results, load the performance parameters in the possession of the
manufacturer and the technician, who can only use them after checking that the installation
is able to reproduce the laboratory conditions. These performances are only achievable after
15/20 hours of operation at rated power.
PARAMETER
UNIT OF
MEASURE
NCA115-2A
NCA150
Heat input
kW
13,1
14,9
Nominal heat output
kW
11,6
13,1
Reduced heat output
kW
5,6
5,6
CO concentration at nominal
reference (13% O
2
)
mg/m
3
130
120
CO concentration at reduced
reference (13% O
2
)
mg/m
3
229
229
Nominal efficiency
%
88,8
88,3
Reduced efficiency
%
90
90
Average consumption
Kg/h
1,24 - 2,63
1,24 - 2,99
Heatable surface
mc
260
300
Flue gas flow rate (min-max)
g/s
5,72 - 9,69
5,72 - 10,45
Draft advised (min-max)
Pa
3 - 5
3 - 8
Flue gas temperature (min-max)
°C
123 - 164
123 - 178
Tank capacity
Kg
18
18
Diameter smoke outlet tube
mm
80
80
Diameter air intake
mm
50
50
Nominal voltage
V
230
230
Nominal frequency
Hz
50
50
Ignition power consumption
W
290
290
Electrical consumption (max-min)
W
100 - 35
105 - 35
Pellet insert weight
Kg
108
120
Powders at 13% O2 Ref.
nominal heat output
mg/m
3
20
20
Energy Class
A +
IEE
125
124
Environmental Certificate
Decree n° 186 del 7/11/2017
N° Test Report
K 3097 2021 T1