Artel NCA115-2A Manual Download Page 16

16 of 36

EN

Pellet insert switching off

To switch off the pellet insert, press the key   on the control board until you read ““

C L E A N I N G   F I N A L

C L E A N I N G   F I N A L

” 

” 

on the display. After the pellet insert has been switched off, the fan continues working for a set time in 
order to grant a fast smokes exhaust from the combustion chamber. 
If you have a model with remote control, you just need to switch the remote control off keeping the key 
pressed for 2 seconds and confirming the selection pressing the key SEND.
If you try to switch on the pellet insert during this phase, the display will show ““

w a i t i n g   c o o l i n g

w a i t i n g   c o o l i n g

”” 

(that means wait for cooling) in order to inform you a switching off phase is running. Wait until the 
cooling phase is completely off and the display shows ““

O F F

O F F

”” before staring a new light up.

REMARKS:

• Do not continuously turn the pellet insert on and off as this could provoke sparks that could shorten 

the life of the electrical components.
• Do not touch the pellet insert with wet hands: the pellet insert has electrical components that could 
produce sparks if handled incorrectly. Only authorized technicians can resolve possible problems.
• Do not remove any screws from the fire chamber without first lubricating them well. 
• Never open the glass door of the pellet pellet insert while the pellet insert is in operation.
• Be sure that the brazier basket is positioned correctly.
• The flue system must be suitable for inspecion. If it cannot be removed, it must have some holes for 
inspection and cleaning.

Join the following instructions to install the
display of a fireplace insert:
• Remove the display from its package (Pict. 10)
• Using a screwdriver, remove the supporting 
bracket from the display holder on the back (Pict. 
11-12)
• Fasten the supporting bracket to the wall using 2 
screws (the fastening system must suit the surface 
where it has to be applied and could require some 
plugs - not provided - for a possible fastening on 
the wall - Pict. 13)
• If you need to invert the flat cable outlet from the 
standard louver of the supporting bracket, remove 
the whole cable and insert it in the hole on the 
other side of the supporting bracket (Pict. 13)
• Install the flat cable where you need it to be put 
(there is the possibility to insert it in a proper duct) 
until it reaches the proper connector on the pcb of 
the fireplace insert
• Insert the display in the supporting bracket (Pict. 
14).

How to install the display

7

G

B

Lighting

• Close the door. Never open the door while

the pellet stove is operating.

• Connect the stove to an outlet with the

appropriate cable received with the stove.

• Place the switch on the rear of the stove at

the “1” position.

• Press the

key for 2 seconds and the

gearcase will begin its lighting cycle.

• Before lighting the stove, carefully read the

use and maintenance manual.

• Remove from the tank all the tools that were

inserted during packaging and be sure that
the tank is free of eventual extraneous
bodies.

• Unroll the environmental probe placed on

the rear of the stove, without placing it on
the heated parts of the stove.

• Correctly connect the pellet stove to the flue.
• Fill the tank with 6mm diameter pellets.
• Open the door and check that the basket is

properly inserted in its slot and that the
flame trap is located in the upper part of the
combustion chamber.

ATTENTION:

During the first lighting it is necessary to
ventilate the environment well, since dur-
ing the first hours of operation unpleas-
ant odours could develop due to fumes
from the paint and the grease in the
tuyère wrapping.

How to install the display

Join the following instructions to install the
display of a fireplace insert:
• Remove the display from its package (Pict. 10)
• Using a screwdriver, remove the supporting

bracket from the display holder on the back
(Pict. 11-12)

• Fasten the supporting bracket to the wall

using 2 screws (the fastening system must
suit the surface where it has to be applied and
could require some plugs - not provided - for
a possible fastening on the wall - Pict. 13)

• If you need to invert the flat cable outlet from

the standard louver of the supporting bracket,
remove the whole cable and insert it in the
hole on the other side of the supporting
bracket (Pict. 13)

• Install the flat cable where you need it to be

put (there is the possibility to insert it in a pro-
per duct) until it reaches the proper connector
on the pcb of the fireplace insert

• Insert the display in the supporting bracket

(Pict. 14).

Pict. 10

Pict. 11

Pict. 12

Pict. 13

Pict. 14

Summary of Contents for NCA115-2A

Page 1: ...d The wall where the product will be placed must not be constructed in wood or in any case made of an inflammable material and in addition it is necessary to maintain a safety distance While the pelle...

Page 2: ...contact the dealer or the Authorized Assistance Center The pellet pellet insert must only be operated in living environments This pellet insert being controlled by an electronic board permits a comple...

Page 3: ...ould be used only for the intended purpose Any other use is considered improper and therefore dangerous Do not put in the hopper other than wood pellets When the pellet insert is operating the surface...

Page 4: ...4 of 36 EN Never turn off the heater by removing electricity Let always complete the shutdown cycle otherwise you may damage the structure and have trouble lighting in the future...

Page 5: ...ery hot Do not touch them except with the appropriate protection The plug of the device power cable must be connected only after installation and assembly of the device and must remain accessible afte...

Page 6: ...ale air extraction kitchen hood other pellet inserts etc which could generate a negative pressure environment A check is necessary with all the equipment on that the drop in pressure between the room...

Page 7: ...let is not provided increase the air inlet section to 340 cm2 The air flow entering from below must not be obstructed by the base or other elements placed inside the installation niche The air flow mu...

Page 8: ...draught and the soot could catch fire Have a professional chimney sweep clean the flue and the chimney at least once a year and before switching on the generator after periods of inactivity Lack of c...

Page 9: ...and the plug of the power lead to the power supply Push the ON button in the back of the stove Lie the stove on the gauge with caution and push it in the chimney until it reaches its correct position...

Page 10: ...heat you are advised to use at least a T250 Keep a distance from flammable and or combustible objects at least 50 cm and from curtains and furniture The pellets are cylinders of compressed wood produc...

Page 11: ...automatically enter the starting phase Press keys 1 and 2 to adjust temperature and use keys 6 and 5 to adjust operating power To turn off the pellet insert hold down key To replace the 3 volt battery...

Page 12: ...the pellet insert the positions of the tubes in the rear view are indicative and tolerance of 10 mm measures with a tolerance of about 10 mm 691 4 57 27 579 279 583 51 5 639 531 691 480 579 279 583 5...

Page 13: ...rt the positions of the tubes in the rear view are indicative and tolerance of 10 mm measures with a tolerance of about 10 mm 711 315 581 5 55 5 637 580 218 6 55 8 O 8 0 195 660 218 6 339 5 57 O 4 5 3...

Page 14: ...e 13 O2 mg m3 130 120 CO concentration at reduced reference 13 O2 mg m3 229 229 Nominal efficiency 88 8 88 3 Reduced efficiency 90 90 Average consumption Kg h 1 24 2 63 1 24 2 99 Heatable surface mc 2...

Page 15: ...read START START The led resistance is switched on After 1 minute the display will read LOAD PELLET LOAD PELLET the pellet insert will load the pellets and continue lighting the resistor Once the app...

Page 16: ...package Pict 10 Using a screwdriver remove the supporting bracket from the display holder on the back Pict 11 12 Fasten the supporting bracket to the wall using 2 screws the fastening system must sui...

Page 17: ...ndicators Chronothermostat This signalises that the automatic single or daily switching on or off of the pellet insert is on The automatic programming can be set only using the remote control Resistan...

Page 18: ...mokes extractor and gear motor are on CADENCE CLEANING The pellet insert is cleaning the brazier The smokes ex tractor is working at its max speed and the pellets loading is minimal WORK The pellet in...

Page 19: ...1 and 2 select whether or not to activate the thermostat on off which allows you to program the automatic ignition of the pellet insert Once the thermostat is activated deactivated press button 4 OFF...

Page 20: ...prog 2 on off 16 thursday prog 2 on off 17 friday prog 2 on off 18 saturday prog 2 on off 19 sunday prog 2 on off 20 start program 3 hour 21 stop program 3 hour 22 monday progr 3 on off 23 tuesday pr...

Page 21: ...mostat It s possible to set two operating ranges delimited by the times set according to the following table where the OFF setting tells the clock to ignore the command The weekly programmer has 4 ind...

Page 22: ...the menu Select the desired language using the keys 1 e 2 08 30 M 3 4 03 STop 1 week end menu level input dialogue PROGRAMME 1 menu level selection meaning possible values 02 03 02 START PROGRAM 1 ac...

Page 23: ...access it STAND BY function is set by default to OFF To activate this feature press 1 on the display you will see STAN BY MODE ON Press SET 3 to con firm and then OFF 4 to leave The STAND BY mode is n...

Page 24: ...o high Switch off the Pellet insert allow it to cool down and perform ordinary cleaning If the problem persists contact an Authorized Assistance Center for cleaning the Pellet insert and the flue ALAR...

Page 25: ...ok at the one end of the detail 1 in the hole of the handle and pull the door 1 Pict 7 opening door Cleaning the brazier and brazier support When the flame assumes a red colour or seems weak and is ac...

Page 26: ...et insert is switched off and cold start up the scrapers of the pipe for heat exchange 5 6 times You need to pull and push the two control levers set between the front grids through which the air flow...

Page 27: ...the metal parts of the pellet insert use a soft cloth dampened with water Never clean the metal parts with alcohol thinners petrol acetone or other degreasing substances If such substances are used o...

Page 28: ...s Installa the pellet insert again Place it on the support and push it slowly until it reaches the apposite check pin Check that the flue system lies perfectly in the T pipe Pict 15 how to remove the...

Page 29: ...performance It is therefore necessary to clean the fans at least once a year Since said operation requires dismantling several parts of the pellet insert have the fans cleaned only by our Technical A...

Page 30: ...onic board sends a warning signal and the display will show SERVICE SERVICE This indicates the need for a thorough cleaning of the pellet insert by a CAT The lack of such cleaning could result in fail...

Page 31: ...r shuts the pellet insert when the flue gas temperature drops below the preset value Electrical safety the pellet insert is protected against violent surges of current ex lightnings by the main fuse 4...

Page 32: ...32 of 36 EN...

Page 33: ...d defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the pellet insert from the power outlet for about one minute and then turn on If the problem persists...

Page 34: ...er ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and replace it with a handful of d...

Page 35: ...se the level in the param eter relative to the speed of the fan exhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increas...

Page 36: ...Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the parameters need to vary the level relating to the loading of pellets 9 Increas...

Page 37: ...ine can only take place following the unquestionable decision by the manufacturer in special cases 3 The Company declares no responsibility for any damage that may directly or indirectly result in per...

Page 38: ...38 of 36 EN NOTES...

Page 39: ...39 of 36 EN NOTES Cod 001247 Date 08 2021...

Reviews: