48
Menu
Use the focus knob to drive the lens focus
scale to its infinity mark.
Press the
OK
soft button or the
USER
but-
ton to set the infinity data point.
Use the focus knob to drive the lens focus
scale to the close focus mark.
Use the
UP
and
DOWN
soft buttons or the
zoom stick to set the close focus value on
the display.
Press the
OK
soft button or the
USER
but-
ton to set the close focus data point.
Repeat this procedure for the other data
points. Make sure to distribute the data
points as evenly as possible over the lens
scale. Use
DOWN
to go back to a previous
set data point for resetting.
It is recommended to set at least 12-14 da-
ta points.
After setting the last focus point, press
FINISH
to finalize the focus programming
procedure.
Press the
OK
soft button to return to the
Select Axis screen.