Getting started
15
Calibrating motors
Calibrate the motor(s) by pressing the
CAL
soft button on the
WCU-4
Home
screen or on the motor controller.
NOTICE
Note: Motors must be recalibrated under the following
conditions:
When a motor is detached from the lens
After changing motors
After changing lenses
After a change in a motor position while powered down
NOTICE
Omitting motor calibration might lead to damage of the lens due
to the high level of motor torque!
Using a Pre-Marked Focus Ring
The use of pre-marked focus rings on the WCU-4 hand unit
requires lens data from the motor controller or camera.
Press the WCU-4
MENU
button. Enter the
Pre-Marked Focus
Rings
menu and select a focus ring. Return to
Home
screen by
pressing the
BACK
or
HOME
button. The selected focus ring will
be indicated next to the numerical focus value in the center of the
screen. The digital focus scale on the display will now align with the
pre-marked focus ring.
You are now ready to shoot.