MAGB2 User Guide
51
V1.7 2021-10-01
19. MAGB2 Error Code Table
MAGB2can detect and show a number of errors in one error code value.
Error position
Error Description
0
Empty Pipe (Air Detect)
1
Excitation
2
Low battery
3
GPRS
4
FOUT overload
5
Relay overload
6
Relay comparator
7
Temperature sensor fault*
8
AD converter error*
9
Pressure alarm*
10
FW Checksum fail
*will be added in future updates
Errors on the display are indicated in hex format. This number must be converted to
binary format! You can use a calculator with hex converting function.
Once the error code has been converted to binary format, each position is related to a different error
(see the table above). Number 1 indicates error and number 0 indicates no error.
Example:
Error shown on display:
Error position:
Readed errors:
76543210
043HEX =
01000011 BIN
Relay comparator / Excitation/ Empty pipe
Position 0
Position 1
Position 15