3. MAGB2 Transmitter Unit
The MAGB2 Transmitter unit is the main part of the flowmeter. It consists of the MAGB2 motherboard, a
graphical display, touch-buttons and transmitter housing. Through the display and with help of the buttons,
you can navigate the meter menu. The following symbols are used in this manual and on the flowmeter
display.
3.1. Main screen
Possible secondary display functions:
Total Volume
This is the total volume counter; the sum of all historical flows for a particular flowmeter. The user is not able
to zero this counter without use of the service password. Direction of flow is ignored for this counter
(negative flow is calculated the same way as positive flow).
Total + Volume
This counter is only credited when the measured medium is flowing in the chosen positive direction. In case
the flow is 0, or if it is flowing in the opposite (negative) direction, the number on the counter remains the
same.
Total - Volume
This counter works the same way as the positive volume counter, yet in the opposite direction. In case the
flow is 0, or flowing in the designated positive direction, the number on this counter will remain the same.
Aux Volume
This is a 2nd total + volume counter. It works the same as the Total + Volume counter, yet with the only
difference being that it can be reset to 0 at any time, with User Settings password.
You can cycle through these 4 indication screens by pressing the up/down buttons on the transmitter.
Unit Volume
Error Code (hex)
Measurement status
Secondary
display function
Unit Flow
Clock
Battery Status
Secondary
display
Status Icons
Actual Flow