ADrive
62
4-KEY READ/WRITE
All parameter of ADrive can be saved to data key and read out from key.
4.1-KEY READ
Parameters in the data key are transferred to inverter.
4.2-KEY WRITE
Parameters of the inverter are transferred to data key
5-FAULT HISTORY
ADrive saves last 256 errors in its memory. By this, facility for maintenance and repairing is
provided.
5.1-Watch Fault List
The list of the faults is displayed on the screen. Last error is number 1 and the oldest error is
number 256.
5.2-Clear Fault List
All faults in the memory are erased.
6-CONTROL TYPE
Determines that if the control of the motor will be in OPEN LOOP (without encoder) mode
or in CLOSED LOOP (with encoder).
6.1 – Control Type
(CT: OPEN LOOP / CLOSED LOOP)
When synchronous motor is selected in the menu, this parameter can be adjusted only as a
closed loop.
7-LANGUAGE
Selection of the language is made by this parameter.
7.1 – Language
(ENGLISH / TURKCE / FRANCAIS)
8-FACTORY DEFAULT
All parameters of the inverter may be changed to factory defaults. For this select YES to
question “
Are you sure to set defaults?”
and approve with
ENTER
button.