ARKEL Elektrik Elektronik Ltd.
Ş
ti. www.arkel.com.tr
08.2012
ADrive
50
TOTAL WORKING:
00004197 Minute
TOTAL WORKING TIME SCREEN
The total working time of driver in minutes is displayed on this
screen.
TOTAL DISTANCE:
00003581 Meter
TOTAL TRAVEL DISTANCE SCREEN
The total travel distance of elevator in meters is displayed on this
screen.
TOTAL TRAVEL:
0000358 RUN/STOP
TOTAL NUMBER OF TRAVEL SCREEN
The total number of travel of elevator in run/stop is displayed on this
screen.
CAN_BUS: 1920 p/s
RS485 : 800 p/s
SERIAL COMMUNICATION MONITORING SCREEN
CAN_BUS:
The number of packets per second of CANbus serial
communication between ENCABIT-Plus module and ADrive.
RS485:
The number of packets per second of RS-485 serial
communication (with ADrive Remote Keypad or lift controllers)
Vref : 1.20 m/s
Vact: 1.19 m/s
SPEED MONITORING SCREEN
Vref:
Reference (target) speed
Vact:
Actual (current) speed
Encabit PI:01000
Enc_pos : 001A3f22
ENCABIT-Plus MONITORING SCREEN
Encabit PI:
The state of the 5 digital inputs (PI1-PI5) on ENCABIT-
Plus module (1: input active / 0: input inactive).
PI1 PI2 PI3 PI4 PI5
Encabit
PI: 0 1 0 0 0
Enc_pos:
The hexadecimal value of 21-bit absolute encoder position.
ADrive SW: V8.30
Encabit SW: V1.03
SOFTWARE VERSION SCREEN
The software version of ADrive inverter and ENCABIT-Plus module.
B.Resistor : % 4
**
▪▪▪▪▪▪▪▪▪▪▪▪▪▪
BRAKING RESISTOR USING SCREEN
The using rate of braking resistor during braking.