background image

001-1

1900-EN rev

. 5

Safety Instructions

3

Intended Use

The 

Semi-Permanent Rack

 is a portable track 

system to be used with Arjo ceiling lift in a homecare 

setting, at nursing homes and other assisted living 

centres. Patient transferring is performed under 

the supervision of a trained caregiver as per the 

instructions outlined in this manual.

WARNING:

 The 

Semi-Permanent Rack

 is 

for transferring patients only. Do not use the 

Semi-Permanent Rack

 for any other purpose.

Using  this 

Semi-Permanent Rack

 outside the 

scope of its intended use could lead to injuries.

Operational Life

This product is designed and tested for a useful life 

of seven (7) years or 10 000 transfers —whichever 

comes first—at maximum safe working load (SWL). 

It is subject to preventive maintenance as specified 

in the "Care and Maintenance" section. 
Time equivalence between the number of transfers 

versus the number of years is explained in the 

following table.

Transfers per Day

Years 

(10 000  transfers)

4

7

6

4.5

8

3.5

WARNING

: The manufacturer cannot ensure full 

safety for a product of which the life span has 

been exceeded. Wear may cause the breakage 

of a part and lead to a patient fall.

The life span is the safe operating time period before 

a complete overhaul is required.
The following factors have an impact on the 

Semi-Permanent Rack

 life span:

•  aging of the unit;
•  transfers per day;
•  weight of the patient;
•  maintenance frequency.

A transfer is defined as the displacement of a patient 

from one point to another. A transfer cycle includes 

a lifting and a descending action.

Equipment Identification

The  unit’s  identification  number  (specification, 

model, serial number) appears on a silver 

nameplate attached inside the track of the 

KWIKtrak

 

Semi-Permanent Rack

General Instructions

Keep these safety instructions with the KWIKtrak 

Semi-Permanent Rack

 at all times. Read the 

assembly instructions before installing or servicing 

this equipment.

WARNING:

 Two persons are required to carry 

out this assembly safely.
Assembling the 

Semi-Permanent Rack

 without 

being assisted could lead to injuries.

How to Use this Manual

To ensure the safe operation of the 

Semi-Permanent Rack

, read the entire manual 

carefully before operating this product.
If anything is not completely understood, please 

contact your local Arjo agent for more details. 

Failure to comply with warnings in this manual may 

result in injuries.
Keep this manual handy and refer to it as required. 

Make sure that all operators are regularly trained in 

the use of the product as per the information found 

therein.
The 

Semi-Permanent Rack

 must be used as per 

these safety instructions.
Anyone using the 

Semi-Permanent Rack

 must also 

have read and understood the instructions in this 

manual.

Foreword

Safety Instructions

Summary of Contents for KWIKtrak 700.11900

Page 1: ...001 11900 EN rev 5 08 2019 INSTRUCTIONS FOR USE KWIKtrak Semi Permanent Rack Model N 700 11900...

Page 2: ...ing to the Arjo group of companies Arjo 2019 As our policy is one of continuous improvement we reserve the right to modify designs without prior notice The content of this publication may not be copie...

Page 3: ...ce 4 Homecare Environment Considerations 4 Symbols Used 5 General Symbols 5 Product Description 6 Semi Permanent Rack System Requirements 7 Floor Requirements 7 Room Assessment 7 Assembling the Semi P...

Page 4: ...or any accidents incidents or lack of performance that occur as a result of any unauthorized modification to its products The equipment must be installed in accordance with these safety instructions A...

Page 5: ...have an impact on the Semi Permanent Rack life span aging of the unit transfers per day weight of the patient maintenance frequency A transfer is defined as the displacement of a patient from one poi...

Page 6: ...comply with the following safety instructions WARNING The assembling disassembling procedure must be performed by two persons Failure to follow this instruction may result in serious injuries to your...

Page 7: ...REF Points out the manufacturer s catalogue number Indicates a potential risk refer to Instructions for Use IFU for details SN Points out the manufacturer s serial number SWL SWL is the maximum load t...

Page 8: ...250 11460 LEG 2 8 225 11425 TOP STEEL PART 2 9 203 11435 PRESSURE STEEL PART 2 10 700 11005 TRACK END STOPPER 2 11 225 11405 T BRACKET 4 12 250 11470 POST 2 13 200 11060 RAIL END CAP WHITE 4 14 000 04...

Page 9: ...mm 48 10 5 mm 7 16 Semi Permanent Rack System Requirements Room Assessment Before installing the Semi Permanent Rack prepare the installation as follows 1 Survey the room where you plan to install th...

Page 10: ...es orientation Plates mate with track brackets 2 Fasten one track bracket onto top of post using two M10X75 hex zinc bolts and corresponding locknuts 3 Tighten using a 17mm socket tool or hexagonal ke...

Page 11: ...on Fig 6 1 Insert one end stopper into the track lower channel Fig 7 2 Install the track between the Track bracket and the pressure plate onto top of first post Fig 8 3 Make sure the track is flush wi...

Page 12: ...0 socket low head zinc screws with appropriate lock washers Fig 15 3 Secure the end stopper in place Fig 16 4 Install a plastic cap at the of the track Final Adjustments 1 Reposition the end stoppers...

Page 13: ...ine the best suitable location for the lift to be placed when it is not being used 2 Align the bottom hooks of the charger station clip to the lower groove on the track 3 Push on the top portion of th...

Page 14: ...all bolts and nuts are properly tightened Make sure that bases are properly adjusted Make sure track is properly assembled to the posts Make sure that all posts are straight Clean the inside of the t...

Page 15: ...e posts Press up on the track to make sure that it is correctly fixed onto posts Trolley does not roll in track smoothly Is track clean Clean track with damp cloth Is trolley centred in track Re centr...

Page 16: ...king load Material Tracks Aluminium Hardware Steel plastic END OF LIFE DISPOSAL Package Cardboard recyclable The Product Components that are primarily be made up of different kinds of metal containing...

Page 17: ...6 87426222 E mail Italy promo arjo com MIDDLE EAST Arjo Middle East FZ LLC Office 908 9th Floor HQ Building North Tower Dubai Science Park Al Barsha South P O Box 11488 Dubai United Arab Emirates Dire...

Page 18: ...Page intentionally left blank...

Page 19: ...Page intentionally left blank...

Page 20: ...on diagnostics and the effective prevention of pressure ulcers and venous thromboembolism we help professionals across care environments to continually raise the standard of safe and dignified care Ev...

Reviews: