13.3 Secondary fan settings
Figure 14. SECONDARY FAN -settings
The primary fan power is determined between 0-100% for each effect point of
the chart. The system calculates the intermediary power percentage
automatically. The secondary fan fans combustion air from above the fuel,
burning the gassed fuel. See factory settings in section 12.4.
You must enter the
user
password in order to adjust the
SECONDARY FAN -
settings.
14.
Factory settings
Consult the following charts for making adjustments. Combustion air fan
power adjustments should be made by means of a flue gas analyser in order
to ensure clean, efficient combustion. According to user experiences, the
maintenance mode settings in particular require certain initial adjustments.
Power point
Factory
setting
Setting
frequency
Function
UP
0.0%
0-100%
Secondary fan power in upkeep
mode.
21%
15%
0-100%
Secondary fan power at 21%.
50%
30%
0-100%
Secondary fan power at 50%.
75%
45%
0-100%
Secondary fan power at 75%.
100%
65%
0-100%
Secondary fan power at 100%.
Ignition
10%
0-100%
Secondary fan power during Ignition
2 phase.