![Ariterm Arimatic 151 User Manual Download Page 22](http://html1.mh-extra.com/html/ariterm/arimatic-151/arimatic-151_user-manual_2972140022.webp)
v2.00
Ariterm Oy
21.5.2013
21
13.
Effect settings
The control system adjusts the burner effect by controlling the fuel feed
(burner screw pulse and pause time ratio) and the rotation speed of the
primary and secondary fans according to heat load changes.
The programme has 80 effect levels (
upkeep
mode 20%,
effect
mode 21-
100%). The
SETTINGS
-page contains the BURNER SCREW
, PRIMARY
FAN and SECONDARY FAN
-menus for setting the speed of the burner screw
and the rotation speed of the primary and secondary fan (0-100%) in five
power levels: UP, 21%, 50%, 75% and 100%. The programme calculates
intermediate power levels according to these basic settings (e.g. 22, 23,
24…%).
13.1 Burnerscrew settings
Figure 12. BURNER SCREW settings.
Effect point
Factory
setting
Setting
frequency
Function
UP
0.5%
0-100%
Burner screw power in upkeep
mode.
21%
2.0%
0-100%
Burner screw power at 21%.
50%
5.0%
0-100%
Burner screw power at 50%.
75%
8.0%
0-100%
Burner screw power at 75%.
100%
10.0%
0-100%
Burner screw power at 100%.
Ignition
5%
0-100%
Burner screw power during Ignition 2
phase.
Backfire
240s
0-600s
Burner screw operating time when
back fire thermostat is set off. The
Burner screw should be emptied
during this time. The storage stops.