Technical Manual for DGI
- 33 -
Fume exhaust hose
Heat-resistance tape
Water heater joint
Connect the fume
exhaust hose with
larger diameter
2.5.4 Connect the fume exhaust hose
z
Please connect the fume exhaust hose to the water heater top as fig. 1. Seal the connection
between fume exhaust hose and water heater with heat-resistance tape to avoid exhaust
leakage.
z
Please do not install the fume exhaust hose with diameter larger than
Φ
60mm as fig. 2.
z
Do not mount in the fume exhaust hose fire-proof board and other parts that resist normal
combustion and exhaust of water heater.
z
Please keep fume exhaust hose away from curtain and other flammable matters.
z
Do not connect common exhaust hose with our fume exhaust joint of water heater to avoid risk.
Fig 1 Fig2