Recommendations:
At the location to install the heater, fix a leakage alarming and cutting-off unit for gas. Horizontal
instance between the unit and the heater should be less than 4 m, vertical distance between the
unit and ceiling less than 30 cm (for town gas), height from the floor less than 30 cm (for natural
gas, liquefied petroleum gas).
! Attention
An exhausting tube should be installed at the flue outlet to exhaust the fume to outdoors.
! Mind: It is strictly prohibited to install the heater at the places stated below:
(1) Bedroom, dressing-room, darkroom
(2) Basement, electrical appliance and meter room, boiler room.
(3) Sites where is of inflammable, explosive or erosive materials. Such as the places: Beauty
parlor, laundry etc. where the erosive gas is easy to be produced, the erosive gas will rust
the heater badly.
(4) Sites where occur significant vibration or any other factors that may affect the heater’s
normal operation.
2.4 Fixation of the heater
z
Drill the wall and insert 2
×Φ
8 expansion pipe as per the outlook drawing of water heater and
drawn pitch for suspending installation holes.
z
Fix the hanger support with 2
×Φ
8
×
50 screw nails to the wall.
z
Suspend the water heater on the hanger support.
z
Attention:
Considering the water heater will apply about 16kg load on the wall, please take reinforcement
actions if loading capacity is insufficient.
Inlet port.
Here lead directly to the air outdoors.
Summary of Contents for Fi7 16L FF
Page 8: ...Technical Manual for DGI 8 z Dimension drawing 1 3 2 M2 10L FF ...
Page 9: ...Technical Manual for DGI 9 z Dimension drawing Same to M1 10L FF 1 3 3 Fi7 16L FF ...
Page 10: ...Technical Manual for DGI 10 ...
Page 11: ...Technical Manual for DGI 11 1 3 4 Gi7S 11L 16L FFI ...
Page 12: ...Technical Manual for DGI 12 ...
Page 13: ...Technical Manual for DGI 13 1 4 Specification list 1 4 1 M1 10L FF ...
Page 14: ...Technical Manual for DGI 14 1 4 2 M2 10L FF ...
Page 15: ...Technical Manual for DGI 15 1 4 3 Fi7 16L FF ...
Page 16: ...Technical Manual for DGI 16 1 4 4 Gi7S 11L 16L FFI ...
Page 17: ...Technical Manual for DGI 17 1 5 Wiring diagram 1 5 1 M1 M2 10L FF ...