![Ariston Fi7 16L FF Service Manual Download Page 52](http://html.mh-extra.com/html/ariston/fi7-16l-ff/fi7-16l-ff_service-manual_2971907052.webp)
Technical Manual for DGI
- 52 -
28
Fault of sensing probe:
Bad contact
Re-connect
29
Fault of sensing probe:
Carbon deposit
Clean or replace
30
Distance between sensing probe and flame
or is too large
31
Fault of igniter
Replace
32
There’s no grounding for main control board Re-grounding
33
Parameters of main control board is on the
low side
Adjust
34
Drift of parameter of main control board
Adjust
35
Fault of main control board
Replace
99
Other causes
Other causes
01
Air source: stop supplying
Explain and give directives
02
Air source
:
liquefied gas is run out or too
much residue
Explain and give directives
03
Air source
:
caliber of external gas valve is
undersized or not completely open, which
may cause insufficient fuel gas flow
Explain, improve external
air pipe or adjust mixing
ratio of fuel gas and air
04
Air source
:
insufficient fuel gas flow caused
by block of external gas pipe
05
Air source
:
insufficient fuel gas flow caused
by undersized external fuel gas pipe of
connector
06
Small air pressure
Explain, coordinate with
relevant authorities or
adjust mixing ratio of fuel
gas and air
,
07
Unstable air pressure
08
Flame-out phenomenon caused by
excessive air pressure
09
Non-conforming air source
Use another air source
10
Bad and impure air quality
Explain, adjust mixing ratio
of fuel gas and air
11
Air mixed into fuel pipe (new residential
housing/recent moving in)
Evacuate air and then carry
out commissioning
12
Insufficient air volume required by
combustion: improper installation inside
cabinet, which causes insufficient oxygen
supply
Re-installation
Flameout or
flue blocked
during running
“E2”
13 Non-conforming installation: distance Re-installation
Summary of Contents for Fi7 16L FF
Page 8: ...Technical Manual for DGI 8 z Dimension drawing 1 3 2 M2 10L FF ...
Page 9: ...Technical Manual for DGI 9 z Dimension drawing Same to M1 10L FF 1 3 3 Fi7 16L FF ...
Page 10: ...Technical Manual for DGI 10 ...
Page 11: ...Technical Manual for DGI 11 1 3 4 Gi7S 11L 16L FFI ...
Page 12: ...Technical Manual for DGI 12 ...
Page 13: ...Technical Manual for DGI 13 1 4 Specification list 1 4 1 M1 10L FF ...
Page 14: ...Technical Manual for DGI 14 1 4 2 M2 10L FF ...
Page 15: ...Technical Manual for DGI 15 1 4 3 Fi7 16L FF ...
Page 16: ...Technical Manual for DGI 16 1 4 4 Gi7S 11L 16L FFI ...
Page 17: ...Technical Manual for DGI 17 1 5 Wiring diagram 1 5 1 M1 M2 10L FF ...