Technical Manual for DGI
- 32 -
2.5.2 Install the fume exhaust hose - FF
z
The water heater must be mounted with fume exhaust hose
with ID
Φ
60mm. Please do not use the fume exhaust
hose with other diameter.
z
Fume exhaust hose can be extended to 3m/3elbows at
most.
z
Please calculate the hose length and required number of
elbows with below equation:
W=L+Mx2
L: Length of connected hose (m)
M: Number of elbows (pc)
If W>9, do not use the water heater.
z
Front fume exhaust section is indicated as one elbow
included in the total number of elbows.
z
Install the extended pipe with 1/50 inclination downward horizontally.
2.5.3 Install the fume exhaust hose - FFI
z
The water heater must be mounted with fume exhaust hose with ID
Φ
60mm/
Φ
100mm, and the
accessory pipe is 0.75m. Please do not use the fume exhaust hose with other diameter.
z
Fume exhaust hose can be extended to 2m/1bend at most.
z
Install the extended pipe with 1/50 inclination downward horizontally.
1
.
Typical installation case 2
.
Extend horizontally: L
≤
1m
3
.
Extend perpendicularly: L
≤
0.5m
4
.
Two elbows: the extended pipe is between
the two elbows, 0.15
≤L≤0.5m
Summary of Contents for Fi7 16L FF
Page 8: ...Technical Manual for DGI 8 z Dimension drawing 1 3 2 M2 10L FF ...
Page 9: ...Technical Manual for DGI 9 z Dimension drawing Same to M1 10L FF 1 3 3 Fi7 16L FF ...
Page 10: ...Technical Manual for DGI 10 ...
Page 11: ...Technical Manual for DGI 11 1 3 4 Gi7S 11L 16L FFI ...
Page 12: ...Technical Manual for DGI 12 ...
Page 13: ...Technical Manual for DGI 13 1 4 Specification list 1 4 1 M1 10L FF ...
Page 14: ...Technical Manual for DGI 14 1 4 2 M2 10L FF ...
Page 15: ...Technical Manual for DGI 15 1 4 3 Fi7 16L FF ...
Page 16: ...Technical Manual for DGI 16 1 4 4 Gi7S 11L 16L FFI ...
Page 17: ...Technical Manual for DGI 17 1 5 Wiring diagram 1 5 1 M1 M2 10L FF ...