- 36 -
3
.
Adjustment of parameters
3.1 Parameters
3.1.1 M1/M2 10L FF
Gas
Input gas
pressure
(
Pa
)
Output gas
pressure
(
Pa
)
Dia. Of
nozzle
(
mm)
the door of
blower
(
mm)
NG
2000 1290 1.3
No.6
Φ
52
LPG
2800
1270
1.0
No.6
Φ
52
3.1.2 Gi7S 11L FFI
Output gas pressure
(
Pa
)
&
current of proportional valve (mA)
Min. gas pressure P2
Max. gas pressure P2
Gas
Input gas
pressure
(
Pa
)
min. current of
proportional valve
max. current of
proportional valve
Dia. Of
nozzle
(
mm)
the door of
blower
(
mm)
Position
of DIP
200
670
NG 2000
30.3 71.8
1.5 35
2 ON
3 OFF
4 ON
260
800
LPG 2800
31.1 84.8
1.1 40
2 ON
3 OFF
4 ON
3.1.3 Gi7S 16L FFI / Fi7S 16L FF
Output gas pressure
(
Pa
)
&
current of proportional valve (mA)
Min. gas pressure P2
Max. gas pressure P2
Gas
Input gas
pressure
(
Pa
)
min. current of
proportional valve
max. current of
proportional valve
Dia. Of
nozzle
(
mm)
the door of
blower
(
mm)
Position
of DIP
180
650
NG 2000
31.5 74
1.5 35
1ON
2 ON
3 ON
220
750
LPG 2800
31.5 80
1.1 40
1ON
2 ON
3 ON
Summary of Contents for Fi7 16L FF
Page 8: ...Technical Manual for DGI 8 z Dimension drawing 1 3 2 M2 10L FF ...
Page 9: ...Technical Manual for DGI 9 z Dimension drawing Same to M1 10L FF 1 3 3 Fi7 16L FF ...
Page 10: ...Technical Manual for DGI 10 ...
Page 11: ...Technical Manual for DGI 11 1 3 4 Gi7S 11L 16L FFI ...
Page 12: ...Technical Manual for DGI 12 ...
Page 13: ...Technical Manual for DGI 13 1 4 Specification list 1 4 1 M1 10L FF ...
Page 14: ...Technical Manual for DGI 14 1 4 2 M2 10L FF ...
Page 15: ...Technical Manual for DGI 15 1 4 3 Fi7 16L FF ...
Page 16: ...Technical Manual for DGI 16 1 4 4 Gi7S 11L 16L FFI ...
Page 17: ...Technical Manual for DGI 17 1 5 Wiring diagram 1 5 1 M1 M2 10L FF ...