USA MAV500/MKVI Service Manual
Main Board
Table 10-1 Optical Security - Typical Assignment
Switch No. Function
Switch No. Function
0 Main
door
4
Not used
1
Not used
5
Not used
2
Not used
6
Not used
3
Not used
7
Not used
Mechanical Security
The system provides the necessary circuitry to interface eight mechanical security
switches.
Up to eight of the mechanical security inputs can be used for security breach
detection while the power is off (independent channel 0 and 1-7 detection). When the
power is on, a random number is written to a battery-backed register on the Driver
Board (channel 0
−
logic door only). A breach of security (opening of the switch)
while the power is off causes the register to reset. When the power is restored the
absence of the original number indicates a security breach. If a changeover switch is
used, the closing of the normally open contact will also reset the register.
The mechanical security sensor interface has the following specification:
•
Switch type: Single pole, changeover
•
Secure state: normally closed
•
Driving source: 3.3 V DC.
Table 10-2 Mechanical Security - Typical Assignment
No.
Function
Monitored by...
0
Logic Cage
Battery-backed circuit.
1
Top Box
Battery-backed circuit..
2
Mechanical Meters
Battery-backed circuit.
3
Cash Box
Battery-backed circuit.
4
Main Door
Main Board only when machine is powered.
5
Bank Note Stacker
Main Board only when machine is powered.
6 Not
used
Spare.
7
Not used
Spare.
10.4.11 Machine
Peripherals
The Main Board can drive the following peripheral equipment:
•
Hopper
•
Coin handling
•
Bank Note Acceptor
•
Printer
•
Mechanical meters.
28-00486-00
10-17
This document contains confidential information which is proprietary to ATI. It may not be disclosed to any unauthorized parties,
and it may not be copied. All rights reserved.
© Copyright (ATI) Aristocrat Technologies, Inc. 2002.