59
Scan
Scanning mode:
Good-read off-
The trigger button must be pressed to
activate scanning. The light source of imager stops scanning
when there is a successful reading or no code is decoded
after the Stand-by duration elapsed.
Momentary-
The trigger button acts as a switch. Press button
to activate scanning and release button to stop scanning.
Alternate-
The trigger button acts as a toggle switch. Press
button to activate or stop scanning.
Timeout off-
The trigger button must be pressed to activate
scanning, and imager stops scanning when no code is
decoded after the Stand-by duration elapsed.
Continue-
Imager always keeps reading, and it does not
matter when trigger button is pressed or duration is elapsed.
Test only-
For test of scan performance only. It is improper to
be utilized to check the accuracy of transmitted data.
Double read timeout:
It determines the duration of
Double
confirm
. For example, if you set 5 times in
Double confirm
and set 10 milliseconds in
Double read timeout
, the
decoder will decode a bar code 5 times in 10 milliseconds.
You need to turn on
Double confirm
to use this feature.
Double confirm:
It determines how many times the decoder
needs to confirm a bar code.
Supplement Check Counter:
It will be more reliable to read
the barcode with extension (supplement) like UPCE/A or
EAN-8/13, but slow down the decoding speed when this
counter is set more.
Summary of Contents for AS-8020
Page 3: ...3 further information ...
Page 5: ...5 ...
Page 14: ...14 8 Select COM23 depending on your Outgoing COM port to connect ...
Page 20: ...20 ...
Page 36: ...36 Inquiry beep every 50 seconds Inquiry beep every 60 seconds Inquiry beep every 70 seconds ...
Page 38: ...38 Level 6 Level 7 ...
Page 70: ...70 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH E ...
Page 74: ...74 Exit Truncate ending 0 15 00 15 00 ...
Page 80: ...80 Exit Expansion Disable Enable 00 01 ...
Page 116: ...116 Exit Insert group number selection 00 44 00 ffH 00 44 00 ...
Page 120: ...120 Exit UCC EAN128 emulation Disable Enable 00 01 ...
Page 140: ...140 PDF 417 STANDRAD 25 PARA CODE 16K EAN 8 PARA INDUSTRIAL 25 PARA UPCE PARA 87549 ...