Code 39
Read:
Format
Start
“
★
”
Data Digits
( Variable)
Checksum
(Optional)
End
“
★
”
Check-sum verification:
The checksum of Code-39 is
optional and made as the sum module 43 of the numerical
value of the data digits.
Check-sum transmission:
By setting Enable, checksum
will be transmitted.
Max./Min. code length:
Each symbology has own Max./Min.
Code Length. They can be set to qualify data entry. If their
Max./Min. Code Length is zero, the Global Min./Max. Code
Length is in effect. The length is defined as to the actual
barcode data length to be sent. Label with length exceeds
these limits will be rejected. Make sure that the Minimum
length setting is no greater than the Maximum length setting,
or otherwise all the labels of the symbology will not be
readable. In particular, you can see the same value for both
Minimum and Maximum reading length to force the fixed
length barcode decoded.
Truncate leading/ending:
Refer to Truncate leading/ending
of UPCA.
Code Id setting:
Refer to Code ID setting of UPCA.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
Enable
00
01
*
Program
Summary of Contents for AS-8020
Page 3: ...3 further information ...
Page 5: ...5 ...
Page 14: ...14 8 Select COM23 depending on your Outgoing COM port to connect ...
Page 20: ...20 ...
Page 36: ...36 Inquiry beep every 50 seconds Inquiry beep every 60 seconds Inquiry beep every 70 seconds ...
Page 38: ...38 Level 6 Level 7 ...
Page 70: ...70 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH E ...
Page 74: ...74 Exit Truncate ending 0 15 00 15 00 ...
Page 80: ...80 Exit Expansion Disable Enable 00 01 ...
Page 116: ...116 Exit Insert group number selection 00 44 00 ffH 00 44 00 ...
Page 120: ...120 Exit UCC EAN128 emulation Disable Enable 00 01 ...
Page 140: ...140 PDF 417 STANDRAD 25 PARA CODE 16K EAN 8 PARA INDUSTRIAL 25 PARA UPCE PARA 87549 ...