ROUTE OF PIPELINE 

Depending on the position of the unit, the piping may be routed sideway from the left or the right (Fig 1), or vertically from 

the back (Fig 2) (depending on the pipe length of the indoor unit).  
 
 

 

 
 

DRAIN PIPE CONNECTION 

1.

 

Remove the fixed part to pull out pipe of indoor machine from the case. Screw the hexagon nut in the left of the 

joint to the end with your hand. 

2.

 

Connect the connecting pipe to the indoor unit: Aim at the pipe center, tighten the Taper nut with fingers, and then 

tighten the Taper nut with a torque wrench, and the direction is shown in diagram on the right. The torque used is 

shown in the following table. 

Note

Carefully check if there is any damage of joints before installation. The joints shall not be reused, unless 

after re-flaring the pipe. 

 

 
 

WRAP THE PIPING  

1.

 

Use the insulation sleeve to wrap the joint part the indoor unit and the connection 

pipe, and then use insulating material to pack and seal insulation pipe, to prevent 

generation of condensate water on the joint part. 

2.

 

Connect the water outlet with drain pipes, and make the connection pipe, cables, 

and the drain hose straight. 

3.

 

Use plastic cable ties to wrap the connecting pipes, cables and drain hose. Run 

the pipe sloping downward 

 
 
 
 
 

Summary of Contents for GREENSTYLE 12000 UE

Page 1: ...YLE 9000 UE GREENSTYLE 12000 UI GREENSTYLE 12000 UE GREENSTYLE 18000 UI GREENSTYLE 18000 UE GREENSTYLE 24000 UI GREENSTYLE 24000 UE GREENSTYLE SINGLE SPLIT AIR CONDITIONERS R32 Please read this manual carefully before installing and using the air conditioner and retain for future reference V 02 21 ...

Page 2: ... precautions 40 Notices for usage 42 Description of parts 44 Remote controller Guide 45 Wifi Guide 50 Clean and care 54 Troubleshooting 56 Notices for installation 58 Indoor unit installation 63 Outdoor unit installation 70 Maintenance notes 71 ...

Page 3: ...ther than those recommended by the manufacturer Should repair be necessary contact your nearest authorized Argoclima Service Centre Any repairs carried out by unqualified personnel may be dangerous The appliance has to be stored in a room that doesn t have any continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or...

Page 4: ...d is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Don t cut off main power switch during operating or with wet hands It may cause electric shock Don t share the socket with other electric appliance Otherwise it may cause electric shock even fire and explosion Always switch off the device and cut the power supply before ...

Page 5: ...e shall be installed in accordance with national wiring regulations An earth leakage breaker with rated capacity must be installed to avoid possible electric shocks INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE EUROPEAN DIRECTIVE 2012 19 EU At the end of its working life this equipment must not be disposed of as an household waste It must be taken to special local communit...

Page 6: ...cts should be no less than 3 0 mm Fuse Type T3 15AH250V the electricity passing through the fuse cannot be higher than 3 15A For the air conditioner permanently connected to an outlet equip the line with a power switch The current switch must be single pole with a distance between the contacts greater than 3 mm and a residual nominal value not greater than 30mA The power supply circuit must have a...

Page 7: ...it may continue to ventilate for a few minutes to help dry the battery of the indoor unit EMERGENCY OPERATION If the remote control is faulty use the emergency button located under the front panel of the indoor unit see image If this button is pushed with the unit OFF the air conditioner will operate in Auto mode If this button is pushed with the unit ON the air conditioner will stop running AIRFL...

Page 8: ...ESCRIPTION OF PARTS INDOOR UNIT OUTDOOR UNIT Note All the illustrations in this manual are for explanation purpose only Your air conditioner may be slightly different The actual shape shall prevail Emergency button ...

Page 9: ...ies do not mix the new batteries with old ones or mix batteries of different types which could cause failure of the remote controller 7 lf the remote controller is not to be used far a long period of time remove the batteries first lest the leakage from them may damage the remote controller 8 Properly dispose the discarded batteries Fig 1 Fig 2 Fig 3 INFORMATION FOR THE CORRECT DISPOSAL OF BATTERI...

Page 10: ...unit When pressed for the first time F will be selected and the C symbol will no longer appear on the display Press again to select C NOTE Some models do not have the possibility to select the temperature in F this means that when the C F button is pressed the F symbol may appear on the remote control display but the temperature will continue to be displayed in C on that of the air conditioner 3 S...

Page 11: ... button has two functions a HEALTH FUNCTION NOT AVAILABLE b iCLEAN When the remote control is off press the iClean button to activate the iClean function with a maximum duration of 30 minutes The purpose of this function is to clean the evaporator from dust dry the water inside the evaporator and prevent the formation of mold which can cause the spread of bad odors After setting the iClean functio...

Page 12: ...ng the flaps of the indoor unit horizontally 14 Anti F button This air conditioner has a special drying and anti mold function This function is controlled by the remote control in the COOLING DRY and AUTO modes When the air conditioner is operating in the heating mode the indoor fan runs for three minutes on weak ventilation before stopping The purpose of this function is to dry the water inside t...

Page 13: ... the button 3 By pressing the SPEED button you can select the fan speed from LOW MID HIGH AUTO 4 Press the ON OFF button the air conditioner starts to operate 5 Press the ON OFF button again the air conditioner stops FAN mode 1 Press the MODE button select the fan operation mode 2 By pressing the SPEED button you can select the fan speed from LOW MID HIGH 3 Press the ON OFF button the air conditio...

Page 14: ...D AND INSTALL THE CONTROL SOFTWARE The control software can be downloaded and installed as follows 1 For mobile terminals such as smart phones and tablet Android 4 1 and iOS 6 0 or above only search and download AC Freedom from Google Play or App store on and install it on your system 2 You may also use your mobile terminal Android 4 1 and iOS 6 0 or above only to scan the QR code see Fig 1 with a...

Page 15: ...fter changing the connected wireless router is the WI FI module inside the air conditioner needs to be reset following the indications here below When AC is running press HEALTH button 8 times reset successfully after twice beep sounds see Fig 4 Note If the device is not connected successfully please reset the air conditioner Wi Fi in the same way Fig 4 ...

Page 16: ...fter the connected wireless router or access point is changed make sure the mobile device is already connected to the wireless router or access point to be paired with the WI FI module 2 If the configuration is failed press Config faild check items to check them notes about the failure before reconfigure the AC After the configuration is successful click the corresponding AC name to enter the cont...

Page 17: ...the figures in this manual are for reference only so please rely on the actual operation interface APPENDIX A CONFIG FAILED CHECK ITEMS 1 Please check the Wi Fi icon on the air conditioner panel if the icon not display please contact customer service 2 Please make sure the mobile phone network under the current router WI FI environment Close the mobile phone 3G 4G data connection to be connected t...

Page 18: ...onment of the air conditioner is dusty correspondingly increase the number of times of cleaning After removing the filter do not touch the fin part of the indoor unit with the finger and no force to damage the refrigerant pipeline CLEAN THE PANEL Clean the front panel of the indoor unit with a cloth and lukewarm water below 40 C Do not disassemble the panel for cleaning CLEAN THE AIR FILTER Remove...

Page 19: ...er the power is sufficient 5 Check whether there is damage in the mounting bracket of the outdoor unit and if any please contact our local service center MAINTENANCE AFTER USING 1 Cut off the power source of the air conditioner turn off the main power switch and remove the batteries from the remote controller 2 Clean the filter and the unit body 3 Remove the dust and debris from the outdoor unit 4...

Page 20: ...fter defrosting Shutdown Timer may be set If you continue to use please turn it on again The wind blows out but the cooling heating effect is not good Excessive accumulation of dust on filter blocking at air inlet and outlet and the excessively small angle of the louver blades all will affect the cooling and heating effect Please clean the filter remove the obstacles at the air inlet and outlet an...

Page 21: ...ver the surface of the indoor unit When ambient humidity is high water drops will be accumulated around the air outlet or the panel etc This is a normal physics phenomenon Prolonged cooling run in open space produces water drops Close the doors and windows Too small opening angle of the louver blades may also result in water drops at the air inlet Increase the angle of the louver blades During the...

Page 22: ...intenance area is well ventilated The continuous ventilation status should be kept during the entire operation process Check whether there is a fire source or potential fire source in the maintenance area Running fire is prohibited in the maintenance area and the no smoking sign should be hanged Check whether the warning sign is in good condition otherwise replace it Welding If it is necessary to ...

Page 23: ... center SAFETY PRINCIPLES FOR INSTALLATION Fire prevention device shall be prepared before installation Keep installing site ventilated open the door and window Ignition source fire smoking and mobile phones are not allowed to exist in area where R32 refrigerant located Keep leak detector in working state during the installation If R32 refrigerant leakage occurs during the installation you shall i...

Page 24: ...ty and gas It is suggested to use the reserved hole in the roof of the wall REQUIREMENTS OF WALL INSTALLATION PLATE The wall installation plate must meet the relevant national or industrial standards in terms of strength with welding and connection areas rustproofed The wall installation plate and its load carry surface shall be able to withstand 4 times or above the weight of the unit or 200kg wh...

Page 25: ...ence to install the unit according to specific requirements Do not install the unit in locations where there are flammable gases or acid or alkaline substances that may irreparably damage the copper aluminium heat exchangers or internal plastic components Do not install the unit in offices or kitchens where oil vapours mixed with treated air may settle on the exchange coils reducing performance or...

Page 26: ...alling that could cause personal injury or death as well as property loss GROUNDING REQUIREMENTS The air conditioner is the class I electrical appliance and must ensure a reliable grounding Do not connect the grounding wire to a gas pipe water pipe lightning rod telephone line or a circuit poorly grounded to the earth The grounding wire is specially designed and shall not be used for other purpose...

Page 27: ...on 2 Use the type screw to fasten the peg board horizontally mount the peg board on the wall and ensure the lateral horizontal and longitudinal vertical 3 Pull the peg board by hand after the installation to confirm whether it is solid WALL THROUGH HOLE 1 Make a hole with an electric hammer or a water drill at the predetermined position on the wall for piping which shall slant outwardly by 5 10 2 ...

Page 28: ...aper nut with a torque wrench and the direction is shown in diagram on the right The torque used is shown in the following table Note Carefully check if there is any damage of joints before installation The joints shall not be reused unless after re flaring the pipe WRAP THE PIPING 1 Use the insulation sleeve to wrap the joint part the indoor unit and the connection pipe and then use insulating ma...

Page 29: ...ble cross hole at the back of indoor unit and then pull it out from the front side Some models do not have a signal cable 3 Remove the wire clip connect the interconnection cord to the wiring terminal according to the wiring diagram tighten the screw and then fix the interconnection cord with wire clip 4 Put wiring cover back and then tighten the screw 5 Close the panel NOTE The diagram are for re...

Page 30: ...66 V 02 21 INSTALLATION OF OUTDOOR UNIT DIMENSION DRAWING OF OUTDOOR UNIT INSTALLATION ...

Page 31: ...st be added so that the operation and performance of the air conditioner will not be compromised Note 1 This table is for reference only 2 The joints shall not be reused unless after re flaring the pipe 3 After installation check the stop valve cover whether be fixed effectively WIRING CONNECTION 1 Loosen the screws and remove E parts cover from the unit 2 Connect the cables respectively to the co...

Page 32: ...p valve gas and liquid valves and be sure to retighten it afterward to prevent the potential air leakage 1 To prevent air leakage and spilling tighten all connecting nut of all flare tubes 2 Connect the stop valve charge hose manifold valve and vacuum pump 3 Fully open the handle Lo of the manifold valve and apply vacuum for at least 15 minutes and check that the compound vacuum gauge reads 0 1MPa...

Page 33: ...stallation method the following methods may be used to check for suspect leak on areas such as the four connections of the outdoor unit and the cores of the cut off valves and t valves 1 Bubble method Apply of spray a uniform layer of soap water over the suspected leak spot and observe carefully for bubble 2 Instrument method Checking for leak by pointing the probe of the leak detector according t...

Page 34: ... main cause of refrigerant leaks Proceed as shown below 1 Cut the pipe Check the length of the pipe based on the distance between the indoor unit and outdoor unit Cut the required pipe using a pipe cutter tubo pipe tagliatubi pipe cutter inclinato slanted irregolare uneven sbavatura burred 2 Remove burrs Remove burrs with a file ensuring they do not go into 5 Expand the port Expand the port using ...

Page 35: ...efective expand the port again following the procedure described above superficie liscia smooth surface allargamento imperfetto defective expansion lunghezza uguale equal length inclinato slanted superficie danneggiata surface damaged fessurazione cracked spessore irregolare uneven thickness tubo di raccordo union pipe tubo pipe REGULATION EU No 517 2014 F GAS The unit contains R32 a fluorinated g...

Page 36: ...GREENSTYLE 9000 UE Kg 0 53 0 357 Tonn CO2 equiv GREENSTYLE 12000 UE Kg 0 60 0 405 Tonn CO2 equiv GREENSTYLE 18000 UE Kg 0 97 0 654 Tonn CO2 equiv GREENSTYLE 24000 UE Kg 1 30 0 878 Tonn CO2 equiv www argoclima com ...