42
V 02/21
Don’t open the windows and doors
for long time when
the air conditioner
is running.
Otherwise, the cooling or heating
capacity will be weakened.
Don’t stand on the top of the
outdoor unit or place heavy things
on it.
This cloud cause personal
injuries or damage the unit.
Don’t use the air conditioner for
other purposes, such as drying
clothes, preserving foods, etc.
Don't apply the cold air to the body
for a long time.
It will deteriorate
your physical conditions and cause
health problems.
Set the suitable temperature.
It is recommended that the
temperature difference between
indoor and outdoor temperature
should not be too large.
Appropriate adjustments of the
setting temperature can prevent
the waste of electricity.
If your air conditioner is not fitted
with a supply cord and a plug, an
anti-explosion all-pole switch must
be installed in the fixed wiring and
the distance between contacts
should be no less than 3.0 mm.
Fuse Type: T3.15AH250V, the electricity passing through the fuse cannot be higher than 3.15A.
For the air conditioner permanently connected to an outlet, equip the line with a power switch. The current switch must
be single-pole, with a distance between the contacts greater than 3 mm and a residual nominal value not greater than
30mA.
The power supply circuit must have a leakage protection device and an air switch whose rated capacity should be
greater than 1.5 times the maximum current.
NOTICES FOR USAGE
OPERATING RANGE
Cooling mode: from +16°C to +49°C (outdoor temperature)
Heating mode: from -15°C to +30°C
(outdoor temperature)
•
When the temperature is too high, the air conditioner may activate the automatic protection device, so that the air
conditioner could be shut down.
•
When the temperature is too low, the heat exchanger of the air conditioner may freeze, leading to water dripping or
other malfunction.
•
In long-term cooling or dehumidification with a relative humidity of above 80% (doors and windows are open), there
may be water condenses or dripping near the air outlet.