63
V 02/21
OTHERS
•
The connection method of the air conditioner and the power cable and the interconnection method of each
independent element shall be subject to the wiring diagram affixed to the machine.
•
The model and rating value of the fuse shall be subject to the silkscreen on corresponding controller or fuse sleeve.
INSTALLATION OF INDOOR UNIT
DIMENSION DRAWING OF INDOOR UNIT INSTALLATION
MOUNTING PLATE
1.
The wall for installation of the indoor unit shall be hard and firm, so as to
prevent vibration.
2.
Use the "+" type screw to fasten the peg board, horizontally mount the peg
board on the wall, and ensure the lateral horizontal and longitudinal vertical.
3.
Pull the peg board by hand after the installation, to confirm whether it is solid.
WALL-THROUGH HOLE
1.
Make a hole with an electric hammer or a water drill at the predetermined
position on the wall for piping, which shall slant outwardly by 5°-10°.
2.
To protect the piping and the cables from being damaged running through the
wall, and from the rodents that may inhabit in the hollow wall, a pipe protecting
ring shall be installed and sealed with putty.
Note: Usually, the wall hole is Φ60mm~Φ80mm. Avoid pre
-buried power wire
and hard wall when making the hole.