18
Switch the monitor on to enter Advanced setup mode (Par. 9.2), and set the parame
-
ters below.
9.4
Language
Ok
Esc
ULTRASONIC CONTROLLER
Auto
1/3
Language
Italian
1/3
2/4
Setting user’s language
• Italiano
• English
• Espanol
• Portugues
1
) Scroll the parameters and select
Language
.
2
) Confirm.
3
) Edit the value.
4
) Confirm setting.
9.5
Setting measurement units
Unit of measure
E
Ok
Esc
ULTRASONIC CONTROLLER
Auto
1/3
1/3
2/4
Setting measurement units
• EU
(l/ha, km/h, m, cm/imp)
• US
(gpa, mph, ft, in/pls)
1
) Scroll the parameters and select
Unit of measure
.
2
) Confirm.
3
) Edit the value.
4
) Confirm setting.
9.6
Speed sensor
Speed sensor
Disable
d
Ok
Esc
ULTRASONIC CONTROLLER
Auto
1/3
1/3
2/4
Set speed sensor
• Disabled
no speed sensor installed. Monitor will calculate
boom opening/closing time according to the speed set by operator
(simulated speed, Par. 10.2).
• Enabled
speed sensor installed. Wheel constant should be
set to ensure correct sensor reading (Par. 9.7).
1
) Scroll the parameters and select
Speed sensor
.
2
) Confirm.
3
) Edit the value.
4
) Confirm setting.
9.7
Costante ruota
Ok
Esc
ULTRASONIC CONTROLLER
Auto
1
1
2
Wheel constant
50.00 cm/imp
Set wheel constant
(pulses from speed sensor installed on the
wheel) for speed calculation:
Only if speed sensor is ENABLED (Par. 9.6)
1
) Scroll the parameters and select
Wheel constant
.
2
) Confirm.
3
) Select manual or automatic mode.
4
) Confirm and carry on with steps specified in Par. 9.7.1 o 9.7.2.
3
Manual setup
3
4
Automatic calc.
CONTINUES