10
6
CONNECTING THE CABLE TO THE CONTROL UNIT AND SERVICES
• Use only the cables provided with the ARAG monitors.
• Take care not to break, pull, tear or cut the cables.
• Use of unsuitable cables or cables not provided by ARAG automatically voids the
warranty.
• ARAG is not liable for damage to the equipment, persons, animals or things caused
by failure to observe the above instructions.
6.1
Connecting the multi-pin connector
Connect the multi-pin connector to the panel and connect the other end of its cable to the control
unit. Make sure that it is correctly fitted and turn the collar clockwise until it locks in place.
6.2
Connecting the valves
• All valve connectors must be equipped with gaskets before installation (Fig.
4
).
• Make sure the gaskets are correctly fitted to avoid infiltration of water when opera
-
ting the control unit.
Fit the connectors to the valves following the markings given in the general system installation
diagram in your possession (Par. 4.1 - Recommended system configuration).
• Remove the protector cap (
1
, Fig. 4) from the electrical valve.
• Fit the gasket (
2
) onto the connector (
3
) and push the connector fully on (
4
):
take care not to
bend the valve’s electrical contacts
.
• Tighten screw (
5
) fully down.
Fig. 4