"Pool / Spa" Button Isn't Working
ISSUE
The "Pool / Spa" button is disabled if the following devices have been configured on the heat pump.
Check with installer if unsure of devices enabled on heat pump.
l
A 2-wire external controller.
l
A 3-wire external controller.
l
A "SMART" external controller.
l
An external flow switch.
RESOLUTION
If not used to operate the heat pump, deactivate the external control device.
Schedule Not Working
ISSUE
A device isn't operating as scheduled.
RESOLUTION
l
Confirm the group has an appropriate schedule program.
l
Confirm the schedule mode is set to "AUTO" and the scheduled program mode is set to "ON".
l
Confirm the time is set correctly in the system.
Water Coming From Heat Pump
ISSUE
The water may be normal condensation produced as a by-product of the heat pump's refrigeration
process.
The heat pump can produce up to 8 to 10 gallons (30 to 38 liters) of condensation per hour depending on
the humidity of the ambient air. Determine if the water is condensation or a possible leak.
RESOLUTION
1. Deactivate heat pump, leaving the filter pump on. After several hours, determine if the water is still coming
from the heat pump.
2. If using chlorine or bromine as a pool/spa sanitizer, test the water around the heat pump using a test strip. If
the test strip indicates that chlorine or bromine is present, a leak may exist.
PLEASE NOTE -
If desired, a kit is available to re-direct condensation water away from the heat pump.
l
Condensation Drain Kit (# STK0202)
4
-
T
roubl
es
hoot
ing