Page - 37
Available freeze protection options:
l
"PROTECT ON SETPOINT" can be adjusted from 33° F to 39° F (.6° C to 4° C). The
default is 37° F (3° C).
l
"PROTECT OFF SETPOINT" can be adjusted from 40° F to 45° F (4° C to 7° C). The
default is 43° F (6° C).
l
"CYCLE TIME" can be adjusted from 5 to 20 minutes.
Enter "Advanced" menus, then proceed
IF UNIT IS ASLEEP,
SWIPE TO WAKE UP
A
PRESS MENU
BUTTON
B
USE ARROWS TO
"SYSTEM"
C
PRESS "ENTER"
D
USE ARROWS TO
"ADVANCED"
E
PRESS "ENTER"
1
USE ARROWS TO MENU
"FREEZE PROTECT"
2
PRESS "ENTER"
TO EDIT
3
USE ARROWS TO
"CYCLE TIME"
4
PRESS "ENTER"
TO EDIT
5
USE ARROWS
TO EDIT
6
PRESS "ENTER"
TO SAVE
MENU TO EXIT, PRESS
& HOLD TO STATUS
2
-