Page - 42
10. Adjust valves in the following order using the temperature chart provided.
a. Adjust the valve that controls water exiting the heat pump until the correct temperature differential is
achieved. Match the temperature measured with a temperature probe to the chart.
b. Wait for water temperatures to stabilize. Then check the temperature again. Re-adjust the valve as needed.
11. Mark valves at these positions for future reference.
HEAT EXCHANGER
TYPE
MODEL
TEMPERATURE
Titanium ThermoLink
®
SQ120R
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
SQ125
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
SQ145
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
SQ150VS
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
SQ166R
3° to 8° F
(1.7° C to 4.4° C)
Titanium ThermoLink
®
SQ225
4° to 9° F
(2.2° C to 5° C)
Tube-in-Tube
T035
1° to 4° F
(.5° C to 2.2° C)
Tube-in-Tube
T055
2° to 5° F
(1.1° C to 2.8° C)
Tube-in-Tube
T075
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
T090
3° to 6° F
(1.7° C to 3.3° C)
Titanium ThermoLink
®
T115
3° to 7° F
(1.7° C to 3.9° C)
Titanium ThermoLink
®
T135
4° to 8° F
(2.2° C to 4.4° C)
Titanium Tube-in-Tube
T170
3° to 7° F
(1.7° C to 3.9° C)
Titanium Tube-in-Tube
TC500
2° to 5° F
(1.1° C to 2.8° C)
Titanium ThermoLink
®
TC1000
2° to 5° F
(1.1° C to 2.8° C)
Titanium ThermoLink
®
TC1500
3° to 7° F
(1.7° C to 3.9° C)
Table 3 - Temperature Chart
3
-
A
ppe
ndi
x
Summary of Contents for TropiCal T170
Page 2: ......
Page 53: ...Page 49 Data Plate Example Model Number Example 3 Appendix ...
Page 54: ...Page 50 3 6 Menu Trees 3 Appendix ...
Page 55: ...Page 51 3 Appendix ...
Page 56: ...Page 52 3 Appendix ...
Page 73: ......