R
BK
BK
BK
BK
BL
BL
BR
BR
V
V
R
P
Y
GR
Y
GR
BK
BK
BK
BK
BK
BK
BL
BL
BL
LOW
PRESSURE
SWITCH
CONTACTOR
COMPRESSOR
TRANSFORMER
REVERSING VALVE
POWER BOARD
HIGH
PRESSURE
SWITCH
SOURCE WATER IN TEMPERATURE SENSOR
POOL WATER IN TEMPERATURE SENSOR
BK
BK
POOL SIDE
WATER FLOW
SWITCH
CONTROL PANEL
TO LINE VOLTAGE
BL
CALL-FLEX
PUMP STARTER CONNECTIONS
L1 L2 GND
T1 L1 P1
T2 L2 P2
FROM TIME
CLOCK LINE SIDE
GROUND
BL
BL
BL
T
BK
R
BK
BK
SOURCE WATER OUT TEMP SENSOR
BK
BK
Y
Y
R
BL
P
R
T
BK
BK
BK
BK
SOURCE SIDE
WATER FLOW SWITCH
POOL WATER OUT
TEMP SENSOR
BK
BK
BK
BK
BK
BK
SOURCE PUMP RELAY
FIELD WIRED LINE VOLTAGE
COLOR CODE
BK: BLACK BL: BLUE BR: BROWN GR: GRAY R: RED V: VIOLET Y: YELLOW W: WHITE
FIELD WIRED 24 VAC
LINE VOLTAGE
OPTIONAL
24VAC
REVISION TABLE
REV.
PCA NUMBER/DESCRIPTION
CHANGED BY
DATE
REL-B
ADDED SOURCE PUMP RELAY (OPTIONAL) & FLOW SWITCHES;
RELOCATED POOL OUT AND SOURCE IN TEMP SENSORS
RENEEC
6/6/2019
D
C
B
A
8
7
6
5
4
3
2
1
D
C
B
A
8
7
6
5
4
3
2
1
NOTES UNLESS OTHERWISE SPECIFIED: 1. USE COPPER CONDUCTORS ONLY. 2. TO BE WIRED IN ACCORDANCE WITH NAT'L ELEC (NEC) & LOCAL CODES. 3. CONNECT TRANSFORMER TO CORRECT VOLTAGE. 4. CUT RED WIRE ON PHASE ROTATION MONITOR FOR D-VOLT 5. LINE VOLTAGE CODES:
B: 208-230VAC/60HZ/3Φ D: 380-415VAC/50HZ/3Φ G: 460VAC/60HZ/3Φ
Last Revision:
01/04/18
DO NOT SCALE DRAWING
CAD GENERATED DRAWING,
DO NOT MANUALLY CHANGE
DIAGRAM,WIRING,3-PH,WATERSOURCE
The Innovative Leader In
Pool & Spa Water
Conditioning Equipment
DATE:
LTM0946
RBC
PROJECT ENG:
12/12/2018
CHK'D BY:
RBC
1:4
RBC
SHEET OF
CAD FILE:
1
INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
AQUACAL AUTOPILOT, INC. ANY
REPRODUCTION IN PART OR WHOLE
WITHOUT WRITTEN PERMISSION OF
AQUACAL AUTOPILOT, INC. IS PROHIBITED.
TOLERANCES:
DECIMALS ANGLES
REVISION
2737 24th St. No.
St. Petersburg, FL 33713
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE
INCHES [MILLIMETERS]
1
DESCRIPTION
SCALE
RBC
DATE:
DWG SIZE
9/10/2018
REL-F
MATERIAL
DWG. NO.
MODELED BY:
LTM0944
A
DRAWN BY:
TBD TBD
FINISH
Summary of Contents for AutoPilot SP05
Page 2: ......
Page 9: ...Page 5 Water Source Top View Water Source Side View 1 Installation...
Page 10: ...Page 6 1 3 Dimensions Water Source WS03 WS05 Water Source WS10 1 Installation...
Page 31: ...Page 27 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Page 32: ...Page 28 1 Installation...
Page 36: ...Page 32 1 Installation...
Page 39: ...Page 35 1 Installation...
Page 43: ...Page 39 1 Installation...
Page 44: ...Page 40 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Page 48: ...Page 44 1 Installation...
Page 50: ...Page 46 1 Installation...
Page 53: ...Page 49 1 Installation...
Page 56: ...Page 52 1 Installation...
Page 58: ...Page 54 1 Installation...
Page 61: ...Page 57 1 Installation...
Page 63: ...Page 59 1 Installation...
Page 83: ...Page 79 l Follow all National Electric Codes NEC and or State and Local guidelines 3 Appendix...
Page 88: ......