Page - 14
SunPower SP05 (Titanium / Cupronickel Exchanger Combination)
1.4.e In-Line Chlorine Feeders
Place in-line chlorinators downstream from the heat pump and as low in elevation as possible.
l
If an erosion type feeder is used, it is recommended that a Hartford Loop be installed to protect internal heat
pump components.
l
A Hartford Loop is not necessary with a Salt Chlorine Generator.
Heat Pump with Hartford Loop
1.4.f Water Flow Rates
Maintain water flow rates as indicated. Please note, these specifications relate to the heat pump only. Code-
specified whole system turnover rates must be satisfied.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Water flow exceeding maximum flow rates will negatively affect the total pool filtration performance and may
damage the heat pump. This will not be covered under the equipment warranty.
Water Source
MODEL
SOURCE
HEAT EXCHANGER TYPE
FLOW RATES
MINIMUM
MAXIMUM
WS03
Source-Side
Titanium ThermoLink
®
20 GPM (75.7 L/min)
70 GPM (265 L/min)
Cupronickel
10 GPM (37.9 L/min)
14 GPM (53 L/min)
Pool / Spa
Titanium ThermoLink
®
30 GPM (113.6 L/min) 70 GPM (265 L/min)
1
-
Ins
ta
ll
at
ion
Summary of Contents for AutoPilot SP05
Page 2: ......
Page 9: ...Page 5 Water Source Top View Water Source Side View 1 Installation...
Page 10: ...Page 6 1 3 Dimensions Water Source WS03 WS05 Water Source WS10 1 Installation...
Page 31: ...Page 27 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Page 32: ...Page 28 1 Installation...
Page 36: ...Page 32 1 Installation...
Page 39: ...Page 35 1 Installation...
Page 43: ...Page 39 1 Installation...
Page 44: ...Page 40 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Page 48: ...Page 44 1 Installation...
Page 50: ...Page 46 1 Installation...
Page 53: ...Page 49 1 Installation...
Page 56: ...Page 52 1 Installation...
Page 58: ...Page 54 1 Installation...
Page 61: ...Page 57 1 Installation...
Page 63: ...Page 59 1 Installation...
Page 83: ...Page 79 l Follow all National Electric Codes NEC and or State and Local guidelines 3 Appendix...
Page 88: ......
Page 89: ......