Page - 30
NOTICE
Failure to heed the following may result in damage to equipment.
l
Do not use an electric heater connection on external controllers for
heat pump wiring.
This can cause damage to external controllers, heat
pumps, and pad equipment. This damage is NOT covered by warranty.
l
The wire size connecting the external controller to the heat pump must be 22-
gauge, 2-conductor, low-voltage wire.
l
Use the two middle data lines on the external controller's standard communication port (RS-485). Do not use the
outside power or ground connection on the port.
c.1 Connecting Smart Bus Controllers
External Controller
Communication Port
Wire Connections
1. Deactivate power to heat pump and external controller.
2. Remove electrical access panels on the heat pump and external controller.
3. Route 22-gauge, 2-conductor, low-voltage wires from the external controller
communication port (com port) to the low voltage side of the heat pump's electrical
enclosure. Do not use the power or ground wire.
Figure 1
4. Connect control wires to the heat pump's "Port B" of the
microprocessor as indicated. See
l
It is OK to double up wires at the external controller
connection if necessary.
l
If, for example, the external controller is using the data
port for an indoor controller, add wires to the existing
configuration.
Connectors can be removed from
terminals for ease in connecting wires. See Figure 3
Typically a smart bus controller will have four wires on its smart bus for a heat pump. The
power and ground (usually the 1st and 4th wire) are not used.
Figure 2
Figure 3
1
-
Ins
ta
ll
at
ion
Summary of Contents for AutoPilot SP05
Page 2: ......
Page 9: ...Page 5 Water Source Top View Water Source Side View 1 Installation...
Page 10: ...Page 6 1 3 Dimensions Water Source WS03 WS05 Water Source WS10 1 Installation...
Page 31: ...Page 27 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Page 32: ...Page 28 1 Installation...
Page 36: ...Page 32 1 Installation...
Page 39: ...Page 35 1 Installation...
Page 43: ...Page 39 1 Installation...
Page 44: ...Page 40 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Page 48: ...Page 44 1 Installation...
Page 50: ...Page 46 1 Installation...
Page 53: ...Page 49 1 Installation...
Page 56: ...Page 52 1 Installation...
Page 58: ...Page 54 1 Installation...
Page 61: ...Page 57 1 Installation...
Page 63: ...Page 59 1 Installation...
Page 83: ...Page 79 l Follow all National Electric Codes NEC and or State and Local guidelines 3 Appendix...
Page 88: ......
Page 89: ......