GENERAL LAYOUT OF A SHOWER INSTALLATION
A TYPICAL INSTANTANEOUS ELECTRIC
SHOWER INSTALLATION
Plan your own installation carefully. Check on the
nearest and most readily accessible rising mains
water supply, this may be beneath the bath or in
the loft, where it feeds the cold water storage
tank. Use only the cold rising water main supply.
Do not connect the shower unit to the outlet from
the cold water tank.
Avoid connecting the shower unit, if possible,
where it will be affected by water drawn off by
other appliances, e.g. From the mains feed to the
W.C. This may cause a drop in pressure too low
for the shower unit to work correctly.
An isolating valve must be fitted to comply with
water regulations and for servicing purposes.
ISOLATING
STOP TAP
DOUBLE POLE
HEATER SWITCH
WALL MOUNTED
IN ACCORDANCE
WITH LOCAL
AUTHORITY
REGULATIONS
COLD WATER
MAINS SUPPLY
SEPARATE PERMANENTLY
CONNECTED SUPPLY
FROM CONSUMER UNIT