PLUMBING CONNECTIONS
The shower unit is supplied for both left
and right hand installation.
To plumb the unit on the left you must
remove the blanking cap and refit it to the
inlet pipe on the right hand side of the unit
ensuring the metal fixing clip is pushed
firmly into the groove.
When leak testing the installation you must
ensure there are no leaks from this area.
Turn off the water supply at the isolating stop
tap. Having determined the direction of the inlet
water supply: It is necessary to remove the
appropriate plastic section from the back plate,
before commencing with the installation.
A for Rear Left - B For Rear Right
We have incorporated into the bottom right &
left hand side of the back plate removable trim
sections to allow easy access when connecting
the water supply.
Connect the mains water supply to the inlet of
the shower unit using a 15mm copper, stainless
or plastic pipe with a 15mm compression elbow
or 15mm push-fit elbow.
Do not use excessive force when making the
connection to the unit.
IMPORTANT
To comply with water regulations, building regulations or any specific local water company regulations and
should be in accordance with BS EN 806. A double check valve must be fitted with all flexible shower
accessories where it is possible that the showerhead may come into contact with used water
i.e. In the bath or shower tray.
IMPORTANT
Before turning on the water supply to the shower unit the water supply pipe should be flushed out to remove
debris. After flushing the pipework ensure that the shower unit is positioned squarely on the wall and tighten
the screws. Tighten all plumbing connections and check the pipework for leaks.