background image

Section #: Title

 

 

 7

 

©Aqua-Hot®

 600D and 675D Use and Care Guide

 

Heating System Features 

Switches 

 

The Aqua-Hot Heating System is controlled by two 

switches, the burner switch and the electric element switch. 
This style of Aqua-Hot is equipped with an Engine Preheat ele-
ment as well. When one or both of the burner or electric ele-

ment switches are in the “ON” position, it will supply the nec-

essary heat to the boiler tank. Keep in mind that the Aqua-Hot 
must be at operating temperature for the heating zones and 
hot water to function properly. Please contact the specific 
coach dealer for the exact location of switch locations. 

 

The Aqua-Hot interior switch panel has a high/low 

switch that will operate in conjunction with the electric ele-
ment switch. 

• 

Low Switch 
 

Moving the High/Low switch to the “LOW” position will

 

 

energize one of the two AC elements inside of the 

 

Aqua-

Hot. On the “LOW” setting, allow 1

-2 hours for  

 

the Aqua-Hot to reach operating temperature. 

• 

High Switch 
 

Moving the High/Low switch to the “HIGH” position 

 

will energize both AC electric elements within the 

 

Aqua-Hot, providing adequate heat for light-duty heat-

 

ing and hot water needs. Allow 30 minutes to 1 hour 

 

for the Aqua-Hot to heat to operating temperature 

 

with the “HIGH” setting activated.

 

Thermostats 

 

The interior room thermostat can be set at a desired 

temperature, signaling to the Aqua-

Hot that it is “calling for 

heat.” Once this occurs, the Aqua

-Hot circulation pump, interi-

or heat exchangers, and heat source will be activated, thereby 
providing heat to the coach. 

NOTE: The fresh water thermostat controls the bay heating 
area and should NOT be set below 40°F to prevent freezing 
of the domestic water storage system. Please contact the 
specific coach dealer for the exact location of the thermostat 
controls. 

Summary of Contents for 675-D

Page 1: ...USE AND CARE GUIDE 600SERIES 600D and 675D with...

Page 2: ......

Page 3: ...nit This guide should be maintained in legible condi tion and kept in a safe accessible location for future review Should you have any suggestions how we can better serve you please do not hesitate to...

Page 4: ...uch more like home Comfort Zone 4 Low Emissions Aqua Hot s new low emission systems are fumeless and odorless It s good for you good for your neighbor and good for the environment Comfort Zone 5 Over...

Page 5: ...Measuring Anti Freeze using a Refractometer 17 Owner s Service Log 18 19 Warranty Limited Warranty Statement 20 Caution Notes As you read this information take particular note of the NO TICE CAUTION...

Page 6: ...material Use caution when working on or near the propane gas system DO NOT connect the 12V DC power to the Aqua Hot if the RV or home requires welding At maximum operating temperatures the coolant wi...

Page 7: ...AC Wiring Ports 6 Domestic Water Connections 7 Domestic Water Access Panel 8 Diesel Burner 9 Drain Valve 10 Diesel Fuel Inlet Outlet Ports 11 Engine Preheat Inlet Outlet Ports 12 Air Relief Valve 13...

Page 8: ...e Aqua Hot to heat from one of or a combination of the following heat sources 1 AC Electric Elements When plugged into shore power or operating on a generator the AC Electric Elements may be utilized...

Page 9: ...o the LOW position will energize one of the two AC elements inside of the Aqua Hot On the LOW setting allow 1 2 hours for the Aqua Hot to reach operating temperature High Switch Moving the High Low sw...

Page 10: ...ted as needed to maintain the set interior temperature Keep in mind that in some conditions the BURNER and ELECTRIC switches must both be in the ON posi tion to provide enough heat to maintain interio...

Page 11: ...is opened The heated antifreeze and water solution flows through the hydronic heating system transfer ring heat to the heat ex changer which is then transferred to the sur rounding zone The cooled ant...

Page 12: ...minate and the diesel burner is not functioning locate the Reporter and check the following 1 Check the Reporter s fault screen for any faults associat ed with this unit 2 Check for loose wire connect...

Page 13: ...home screen and any tests which are underway at that time will be ended Pumps and Zone Fans Pumps and Zone fans are activated individually and remain active until the Reporter times out or the test is...

Page 14: ...e and the water quality recommendations for the Aqua Hot antifreeze and water heating solution Reference appendix D for the proper tool and instructions for usage in measuring the system s antifreeze...

Page 15: ...winterize the Aqua Hot system completely fill the fresh water storage tank Open and close the interior and exterior faucets one at a time until only clear water is pre sent Disinfecting the Domestic W...

Page 16: ...vel at the expansion tank If the level is low ref erence the maintenance section of this guide for refilling instructions If the Aqua Hot s failure to operate is not resolved with the aforementioned c...

Page 17: ...in high levels of chemical rust inhibitors Due to their potentially hazardous properties they should never be used in an Aqua Hot heating system Appendix B Antifreeze Mixture Water Quality Recommendat...

Page 18: ...quid to a gas Rust and Anti Corrosive Inhibitors Another major function of the antifreeze solution is to protect the internal metal components of the Aqua Hot system from corrosion and rust Antifreeze...

Page 19: ...r Once that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration s...

Page 20: ...Section Title 18 Aqua Hot 600D and 675D Use and Care Guide Service Log DATE SERVICE PERFORMED SERVICE CENTER...

Page 21: ...p 19 Aqua Hot 600D and 675D Use and Care Guide DATE SERVICE PERFORMED SERVICE CENTER Service Log...

Page 22: ...protect the heater s end user from such de fects which would occur in the manufacturing of the product Thus problems due to improper specifications improper installations improper use the use of acce...

Page 23: ......

Page 24: ...eating Systems Inc 7501 Miller Drive Frederick CO 80504 Visit us on line at www aquahot com Call us at 800 685 4298 or 303 651 5500 2018 Aqua Hot Heating Systems Inc Printed In U S A LTE 907 900 Rev C...

Reviews: