background image

p. 

 

 

©Aqua-Hot®

 600D and 675D Use and Care Guide

 

Operating the Aqua-Hot 

Heating System Operation 

Overview: 

 

The heating features are powered by a 12V DC diesel 

burner, and two AC electric elements. These elements, in com-
bination with the diesel burner heat the anti-freeze and water 
heating solution within the Aqua-Hot to provide steady, contin-
uous heat and hot water. 

• 

Diesel 
 

The diesel burner is the primary, and most powerful 

 

heating source within the Aqua-Hot. The diesel burner 

 

can meet all demands for heat and hot water that the 

 

coach may require. It can be activated by simple mov-

 

ing the “BURNER” switch on the interior switch panel 

 

to the “ON” position.

 

• 

Electric 
 

The electric elements are intended as a 

secondary 

 

heat source within the Aqua-Hot, and can provide 

 

light-duty hot water and interior heat in mild condi-

 

tions. The electric elements can be activated by mov-

 

ing the “ELECTRIC” switch, located on the interior 

 

switch panel to the “ON” position. 

 

• 

Engine Preheat 
 

In order to use the Engine Preheat element of the 

 

Aqua-Hot system, both the diesel burner AND the en-

 

gine preheat switch, located on the interior switch 

 

panel, must be in the “ON” position. Allow the engine 

 

preheat element to function for one hour before start-

 

ing the vehicle’s engine.

 

Controlling Heat Levels: 

 

The interior room thermostat can be adjusted to the 

 

desired temperature, and the Aqua-Hot will be auto-

 

matically activated and de-activated as needed to 

 

maintain the set interior temperature. Keep in mind 

 

that in some conditions, the “BURNER” and 

 

“ELECTRIC” switches must both be in the “ON” posi

-

 

tion to provide enough heat to maintain interior tem-

 

perature. 

 

Controlling and Balancing Heating Zones 

 

Set the interior room thermostat for each independ-

 

ent heating zone at the desired temperature. This 

 

feature allows you to customize various temperatures 

 

on each heating zone throughout your coach. 

Using the Water Heating System 

General Information: 

 

The Aqua-Hot system is known as an on-demand hot 

water heating system because hot water is not stored within 
the coach. Instead, when the burner and/or electric elements 
are activated the Aqua-Hot is heated to operating tempera-
ture. Once the Aqua-Hot reaches operating temperature, do-
mestic water is heated as it is supplied to the faucets. There-
fore, simply open a hot water faucet within the coach once the 
system is up to operating temperature, and a continuous sup-
ply of hot water will be available within a few seconds. 

Operation Instructions: 

 

To operate the electric heating elements, or the diesel 

burner, simply move the “BURNER,” and “ELECTRIC” switches 
to the “ON” position. This action will activate the correspond-

ing devices within the Aqua-Hot to begin heating the unit to 
operating temperature. Please note that the electric element 

retains “HIGH” and “LOW” functionality, and this will impact 

the performance of the electric elements accordingly. 

NOTE: The coach must be operating on shore power, or the 
generator must be active in order to utilize the electric ele-
ment functionality of the Aqua-Hot. 

Summary of Contents for 675-D

Page 1: ...USE AND CARE GUIDE 600SERIES 600D and 675D with...

Page 2: ......

Page 3: ...nit This guide should be maintained in legible condi tion and kept in a safe accessible location for future review Should you have any suggestions how we can better serve you please do not hesitate to...

Page 4: ...uch more like home Comfort Zone 4 Low Emissions Aqua Hot s new low emission systems are fumeless and odorless It s good for you good for your neighbor and good for the environment Comfort Zone 5 Over...

Page 5: ...Measuring Anti Freeze using a Refractometer 17 Owner s Service Log 18 19 Warranty Limited Warranty Statement 20 Caution Notes As you read this information take particular note of the NO TICE CAUTION...

Page 6: ...material Use caution when working on or near the propane gas system DO NOT connect the 12V DC power to the Aqua Hot if the RV or home requires welding At maximum operating temperatures the coolant wi...

Page 7: ...AC Wiring Ports 6 Domestic Water Connections 7 Domestic Water Access Panel 8 Diesel Burner 9 Drain Valve 10 Diesel Fuel Inlet Outlet Ports 11 Engine Preheat Inlet Outlet Ports 12 Air Relief Valve 13...

Page 8: ...e Aqua Hot to heat from one of or a combination of the following heat sources 1 AC Electric Elements When plugged into shore power or operating on a generator the AC Electric Elements may be utilized...

Page 9: ...o the LOW position will energize one of the two AC elements inside of the Aqua Hot On the LOW setting allow 1 2 hours for the Aqua Hot to reach operating temperature High Switch Moving the High Low sw...

Page 10: ...ted as needed to maintain the set interior temperature Keep in mind that in some conditions the BURNER and ELECTRIC switches must both be in the ON posi tion to provide enough heat to maintain interio...

Page 11: ...is opened The heated antifreeze and water solution flows through the hydronic heating system transfer ring heat to the heat ex changer which is then transferred to the sur rounding zone The cooled ant...

Page 12: ...minate and the diesel burner is not functioning locate the Reporter and check the following 1 Check the Reporter s fault screen for any faults associat ed with this unit 2 Check for loose wire connect...

Page 13: ...home screen and any tests which are underway at that time will be ended Pumps and Zone Fans Pumps and Zone fans are activated individually and remain active until the Reporter times out or the test is...

Page 14: ...e and the water quality recommendations for the Aqua Hot antifreeze and water heating solution Reference appendix D for the proper tool and instructions for usage in measuring the system s antifreeze...

Page 15: ...winterize the Aqua Hot system completely fill the fresh water storage tank Open and close the interior and exterior faucets one at a time until only clear water is pre sent Disinfecting the Domestic W...

Page 16: ...vel at the expansion tank If the level is low ref erence the maintenance section of this guide for refilling instructions If the Aqua Hot s failure to operate is not resolved with the aforementioned c...

Page 17: ...in high levels of chemical rust inhibitors Due to their potentially hazardous properties they should never be used in an Aqua Hot heating system Appendix B Antifreeze Mixture Water Quality Recommendat...

Page 18: ...quid to a gas Rust and Anti Corrosive Inhibitors Another major function of the antifreeze solution is to protect the internal metal components of the Aqua Hot system from corrosion and rust Antifreeze...

Page 19: ...r Once that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration s...

Page 20: ...Section Title 18 Aqua Hot 600D and 675D Use and Care Guide Service Log DATE SERVICE PERFORMED SERVICE CENTER...

Page 21: ...p 19 Aqua Hot 600D and 675D Use and Care Guide DATE SERVICE PERFORMED SERVICE CENTER Service Log...

Page 22: ...protect the heater s end user from such de fects which would occur in the manufacturing of the product Thus problems due to improper specifications improper installations improper use the use of acce...

Page 23: ......

Page 24: ...eating Systems Inc 7501 Miller Drive Frederick CO 80504 Visit us on line at www aquahot com Call us at 800 685 4298 or 303 651 5500 2018 Aqua Hot Heating Systems Inc Printed In U S A LTE 907 900 Rev C...

Reviews: