 600D and 675D Use and Care Guide

 

Safety and Precautions 

The Aqua-Hot Heating System 

Read and understand all instructions before installing this 
unit. 

• 

Read this owner’s manual before installing or using the 

Aqua-Hot system to reduce the risk of injury to persons or 
damage to equipment. 

• 

The product identity label contains specifications of the 
unit, to what standard it has been tested, and important 
safety notices. 

• 

The Aqua-Hot must be installed in a compartment that is 
closed off from living quarters and accessible only from 
the outdoors. 

• 

Propylene glycol based antifreeze “Generally Recognized 
As Safe” (GRAS) by the FDA must be utilized for antifreeze 

and water heating solution. 

• 

An interlock switch prevents the Aqua-Hot heater from 
operating when the cover is not installed in the correct 
position. 

• 

Should any additional assistance be needed, please con-
tact the Product Application Department at +1 (800) 685-
4298 or +1 (303) 651-5500.

 

• 

Do not store or use gasoline or other flammable vapors or 
liquids in the vicinity of this or any other appliance 

• 

Disconnect electric wiring to the Aqua-Hot system before 
welding or plasma cutting the RV or home to avoid dam-
age to equipment

 

• 

Air pressure to the tank must NOT exceed 20PSI or it will 
cause damage

 

• 

The Aqua-Hot exhaust is HOT and must be kept away from 
heat sensitive material

 

• 

Use caution when working on or near the propane gas 
system

 

• 

DO NOT connect the 12V DC power to the Aqua-Hot if the 
RV or home requires welding

 

• 

At maximum operating temperatures, the coolant will be 
very hot and scalding hot vapor or coolant may result in 

serious burns or injury

 

• 

DO NOT activate the burner until the antifreeze and water 
heating solution has been added to the boiler tank to 
avoid serious damage to the heater

 

WHAT TO DO IF YOU SMELL GAS 

• 

Evacuate all persons from the vehicle

 

• 

Shut off the gas supply at the gas container or source

 

• 

Do not touch any electrical switch or use any phone or 
radio in the vehicle

 

• 

Do not start the engine or electric generator (if equipped)

 

• 

Contact the nearest gas supplier or qualified service tech-
nician for repairs

 

• 

If you cannot contact the nearest gas supplier or qualified 
service technician, contact the nearest fire department

 

• 

Do not turn on the gas supply until the gas leak or leaks (if 
relevant) has been repaired

 

• 

Installation and service must be performed by a qualified 
installer, service agency or gas supplier

 

The Aqua-

Hot’s exhaust is HOT!

 

• 

Do NOT park in areas where dry conditions exist (i.e. 
grassy, dry fields)

 

• 

Do NOT operate the burner inside an enclosed building

 

• 

The heater must be switched OFF when refueling

 

If the information in these instructions is not followed exact-
ly, a fire or explosion may result causing property damage, 
personal injury, or death. 

As with any appliance, allow the Aqua-Hot to completely 
shut down BEFORE disengaging the coach 12V power dis-
connect.

 

Summary of Contents for 675-D

Page 1: ...USE AND CARE GUIDE 600SERIES 600D and 675D with...

Page 2: ......

Page 3: ...nit This guide should be maintained in legible condi tion and kept in a safe accessible location for future review Should you have any suggestions how we can better serve you please do not hesitate to...

Page 4: ...uch more like home Comfort Zone 4 Low Emissions Aqua Hot s new low emission systems are fumeless and odorless It s good for you good for your neighbor and good for the environment Comfort Zone 5 Over...

Page 5: ...Measuring Anti Freeze using a Refractometer 17 Owner s Service Log 18 19 Warranty Limited Warranty Statement 20 Caution Notes As you read this information take particular note of the NO TICE CAUTION...

Page 6: ...material Use caution when working on or near the propane gas system DO NOT connect the 12V DC power to the Aqua Hot if the RV or home requires welding At maximum operating temperatures the coolant wi...

Page 7: ...AC Wiring Ports 6 Domestic Water Connections 7 Domestic Water Access Panel 8 Diesel Burner 9 Drain Valve 10 Diesel Fuel Inlet Outlet Ports 11 Engine Preheat Inlet Outlet Ports 12 Air Relief Valve 13...

Page 8: ...e Aqua Hot to heat from one of or a combination of the following heat sources 1 AC Electric Elements When plugged into shore power or operating on a generator the AC Electric Elements may be utilized...

Page 9: ...o the LOW position will energize one of the two AC elements inside of the Aqua Hot On the LOW setting allow 1 2 hours for the Aqua Hot to reach operating temperature High Switch Moving the High Low sw...

Page 10: ...ted as needed to maintain the set interior temperature Keep in mind that in some conditions the BURNER and ELECTRIC switches must both be in the ON posi tion to provide enough heat to maintain interio...

Page 11: ...is opened The heated antifreeze and water solution flows through the hydronic heating system transfer ring heat to the heat ex changer which is then transferred to the sur rounding zone The cooled ant...

Page 12: ...minate and the diesel burner is not functioning locate the Reporter and check the following 1 Check the Reporter s fault screen for any faults associat ed with this unit 2 Check for loose wire connect...

Page 13: ...home screen and any tests which are underway at that time will be ended Pumps and Zone Fans Pumps and Zone fans are activated individually and remain active until the Reporter times out or the test is...

Page 14: ...e and the water quality recommendations for the Aqua Hot antifreeze and water heating solution Reference appendix D for the proper tool and instructions for usage in measuring the system s antifreeze...

Page 15: ...winterize the Aqua Hot system completely fill the fresh water storage tank Open and close the interior and exterior faucets one at a time until only clear water is pre sent Disinfecting the Domestic W...

Page 16: ...vel at the expansion tank If the level is low ref erence the maintenance section of this guide for refilling instructions If the Aqua Hot s failure to operate is not resolved with the aforementioned c...

Page 17: ...in high levels of chemical rust inhibitors Due to their potentially hazardous properties they should never be used in an Aqua Hot heating system Appendix B Antifreeze Mixture Water Quality Recommendat...

Page 18: ...quid to a gas Rust and Anti Corrosive Inhibitors Another major function of the antifreeze solution is to protect the internal metal components of the Aqua Hot system from corrosion and rust Antifreeze...

Page 19: ...r Once that is complete peer through the eyeglass of the refractometer to continue to the next step Adjust the Boundary Line Once the glycol solution has been properly applied adjust the calibration s...

Page 20: ...Section Title 18 Aqua Hot 600D and 675D Use and Care Guide Service Log DATE SERVICE PERFORMED SERVICE CENTER...

Page 21: ...p 19 Aqua Hot 600D and 675D Use and Care Guide DATE SERVICE PERFORMED SERVICE CENTER Service Log...

Page 22: ...protect the heater s end user from such de fects which would occur in the manufacturing of the product Thus problems due to improper specifications improper installations improper use the use of acce...

Page 23: ......

Page 24: ...eating Systems Inc 7501 Miller Drive Frederick CO 80504 Visit us on line at www aquahot com Call us at 800 685 4298 or 303 651 5500 2018 Aqua Hot Heating Systems Inc Printed In U S A LTE 907 900 Rev C...

Reviews: