AQUADUCT CONTROL UNIT
- 36 -
Aqua Computer GmbH & Co. KG
© 2008-2009
Gelliehäuser Str. 1, 37130 Gleichen, Germany
19.4.
19.4.
19.4.
19.4. Restrictions of the emergency shutdown functions
Restrictions of the emergency shutdown functions
Restrictions of the emergency shutdown functions
Restrictions of the emergency shutdown functions
The emergency shutdown function, if connected and configured prop-
erly, can prevent damages to your hardware. However no protection
can be a hundred percent secure. We therefore deny any liability for
We therefore deny any liability for
We therefore deny any liability for
We therefore deny any liability for
damages that are created by or in spite of using this function.
damages that are created by or in spite of using this function.
damages that are created by or in spite of using this function.
damages that are created by or in spite of using this function. Especially
with the connection as a power button on the motherboard, the emer-
gency shutdown may remain unsuccessful!
19.6.
19.6.
19.6.
19.6. Configuring display contrast on
Configuring display contrast on
Configuring display contrast on
Configuring display contrast on start
start
start
start----up
up
up
up
When switching on the device, the contrast of the display can be regu-
lated by turning the rotary knob. By doing this the start process is ex-
tended and normal operation is temporarily suspended. After the last
movement of the knob it will take a moment before the operation starts!
20.
20.
20.
20. Trouble shooting
Trouble shooting
Trouble shooting
Trouble shooting
20.1.
20.1.
20.1.
20.1. Loading factory defaults on
Loading factory defaults on
Loading factory defaults on
Loading factory defaults on start
start
start
start----up
up
up
up
In individual cases it can occur that the settings stored in the device are
destroyed, for example if the power supply to the device is interrupted
during a writing process. In this case, all default settings can be reinitial-
ized. To do this, hold the rotary knob pressed down when switching on
the device. The Display will read "Factory defaults, please hold 3 sec-
onds". After a successful deletion, the display will confirm loading fac-
tory defaults. Please let go of the knob, the device will restart automati-
cally with default configuration.
NOTE: If the relay is used to switch the ATX-break-line, the computer
will be shut down immediately because also the data of the relay is re-
turned to the default setting. In order to avoid data loss, you should
therefore disconnect all devices except the aquaduct from the PSU prior
to loading the default settings!
Now that you have completely read the instructions, we wish you much
joy with our products. For further questions please do not hesitate to
contact us via e-mail or also in our support forum.