AQUADUCT CONTROL UNIT 

© 2008-2009 

Aqua Computer GmbH & Co. KG 

- 21 - 

 

Gelliehäuser Str. 1, 37130 Gleichen, Germany 

the  speedometer  signal  degenerates  at  a  low  power  output  and  thus 
cannot  be  processed  by  the  aquaduct.  In  this  case  you  should  deacti-
vate this function to regulate the fan independently of the quality of the 
speedometer signal. 
 
8.11. Override 

8.11. Override 

8.11. Override 

8.11. Override on/off

on/off

on/off

on/off    

Enables/disables the override function for this fan channel. 
 
8.12. 

8.12. 

8.12. 

8.12. Hold minimum power

Hold minimum power

Hold minimum power

Hold minimum power    

By  activating  this  function  the  fan  output  is  operated  at  at  least  the  
minimum power in the modes „linear“, „progressive“ and „target value“ 
even if the temperature is below the minimum or target value. 
 
8.13. 

8.13. 

8.13. 

8.13. Back

Back

Back

Back    

Leaves the submenu and returns to the fan selection. 
 
 

9. Menu

9. Menu

9. Menu

9. Menu „Pump“

 „Pump“

 „Pump“

 „Pump“    

9.

9.

9.

9.1. Auto

1. Auto

1. Auto

1. Auto    mod

mod

mod

mode

ee

e    on

on

on

on////off

off

off

off    

This  setting  determines  whether  the pump  is  set  to  a  manually  defined 
rotation  speed  (setting  „Manual  Frequency“)  or  will  automatically  de-
termine its maximum rotation speed and run at this speed (setting „Auto-
matic  frequency“).  Maximum  rotation  speed  varies  depending  on  flow 
resistance of the cooling system. 
 
9.2. Min

9.2. Min

9.2. Min

9.2. Minimum frequency

imum frequency

imum frequency

imum frequency    o

o

o

on/

n/

n/

n/off

off

off

off    

When activated, the pump will automatically restart if the set value for 
minimum frequency cannot be met during start-up of the pump.  
 
9.3. Min

9.3. Min

9.3. Min

9.3. Minimum fr

imum fr

imum fr

imum frequency

equency

equency

equency    

This value defines the minimum frequency equaling a minimum rotation 
speed for the pump. This value is only processed if “minimum frequency 
on/off” is enabled.  
 

Summary of Contents for aquaduct mark 3

Page 1: ...r Str 1 37130 Gleichen Germany Control unit Control unit Control unit Control unit aquaduct User s manual Firmware version 1 05 OS version 2 00 The information contained in this manual is subject to c...

Page 2: ...9 4 2 Override function for quick efficiency adjustment 9 4 3 Display mode 10 5 Device settings 12 5 1 Basic operation 12 5 1 1 Definition of names 12 5 1 2 Principle of assigning sensors to fans 12 5...

Page 3: ...auto 18 8 2 Sensor 2 auto 18 8 3 Set rpm 18 8 4 Manual control 19 8 5 Get maximum rpm 19 8 6 Calibration factor 19 8 7 Maximum power 19 8 8 Minimum power 19 8 9 Control options 20 8 10 Use rpm signal...

Page 4: ...Alarm beeper 26 12 5 Rpm signal on off 27 12 6 Rpm signal on alarm 27 12 7 Rpm signal speed 27 12 8 Back 27 13 Menu Illumination 27 13 1 Sensor 1 auto 27 13 2 Sensor 2 auto 28 13 3 Brighter Darker 28...

Page 5: ...8 1 Regulate water temperature to a target temperature of 40 C 33 18 2 Temperature dependent illumination of the aquaduct 33 18 3 Emergency shutdown of the PC on temperature alarm 34 19 Special notice...

Page 6: ...al components 2 1 2 1 2 1 2 1 power power power power Power supply connector Attach a vacant power connector of your PSU Due to the form of the plug the polarity can not be misin terpreted Do not use...

Page 7: ...ay alarm relay This floating breaking contact can be used for advanced security func tionns for example emergency shutdown functions on alarm condition For using these functions additional accessories...

Page 8: ...the relay connector of the aquaduct If you want to use the relay outlet for con nection to the power switch line of the motherboard the ATX PS_ON line must re main intact For correct op eration the c...

Page 9: ...iency adjustment For quick adjustment of the cooling efficiency the aquaduct 360 720 XT mark III features a configurable override function to adjust all impor tant control parameters just with one sin...

Page 10: ...he screens the display can also be configured to switch to the next screen after a variable time span You can add or remove single screens as well as define sensor names freely which is the reason why...

Page 11: ...Air front 20 0C Air back 20 0C Sensor 5 20 0C Sensor 6 20 0C FAN1 100 FAN2 100 FAN3 100 FAN4 100 Top fan 0 rpm Middle fan 0 rpm Bottom fan 0 rpm Ext fan 0 rpm Top fan 12 0V Middle fan 12 0V Bottom fa...

Page 12: ...ng order capital letters lower case letters space and numbers By se lecting the character the cursor jumps back to the previous posi tion After confirming your selection by pressing the rotary knob th...

Page 13: ...s s s s Calls the submenu to configure the four fan outputs For details see 8 Menu Fans 5 2 4 5 2 4 5 2 4 5 2 4 Pump p Pump p Pump p Pump parameter arameter arameter arameters s s s Calls the submenu...

Page 14: ...power measurement functions For de tails see 15 Menu Power measurement 5 2 11 5 2 11 5 2 11 5 2 11 Fill level measurement Fill level measurement Fill level measurement Fill level measurement Calls the...

Page 15: ...his temperature the assigned fan continues to run at maximum speed 6 4 Alarm 6 4 Alarm 6 4 Alarm 6 4 Alarm temperature temperature temperature temperature Enter the temperature in C here at which the...

Page 16: ...0 C to 100 0 C Default setting is 35 0 C 6 7 6 7 6 7 6 7 C C C Cal al al alibr ibr ibr ibrat at at ati i i ion on on on offset offset offset offset Professional function to calibrate the temperature s...

Page 17: ...r Controller factor This value is only needed if the corresponding fan is in the target value mode The regulator factor is a multiplier for the temperature difference of the target value and causes an...

Page 18: ...trol The entered values are not lost when the operating mode is switched but are saved for the next call 8 1 Sensor 1 a 8 1 Sensor 1 a 8 1 Sensor 1 a 8 1 Sensor 1 auto uto uto uto Activates the contro...

Page 19: ...maximum rpm Get maximum rpm Get maximum rpm Get maximum rpm Reinitializes the aquaduct and determines the maximum speed of the connected fan for the selected fan canal if the fan generates a speed ome...

Page 20: ...e speed curve is dependent on the temperature With climbing temperatures the speed curve begins shal low but climbs steeper as the full load temperature is reached Opposite to the linear regulation th...

Page 21: ...Back Leaves the submenu and returns to the fan selection 9 Menu 9 Menu 9 Menu 9 Menu Pump Pump Pump Pump 9 9 9 9 1 Auto 1 Auto 1 Auto 1 Auto mod mod mod mode e e e on on on on off off off off This se...

Page 22: ...djust the contrast of the LCD display The value entered is represented by a graphical bar 10 3 10 3 10 3 10 3 Minimum brightness Minimum brightness Minimum brightness Minimum brightness This setting d...

Page 23: ...choose if the device should directly activate the USBLCD Mode when booting To leave the USBLCD Mode push the rotary knob 10 9 10 9 10 9 10 9 Page setup Page setup Page setup Page setup Here you can en...

Page 24: ...enu and returns to Settings 11 Men 11 Men 11 Men 11 Menu u u u Relay Relay Relay Relay This menu is used for the configuration of the relay function This func tion requires further components connecti...

Page 25: ...to shutdown the PC in case of an alarm event A correct setup in this menu is crucial for the emergency shutdown function of the PC If the relay is connected to the power button connection on the mothe...

Page 26: ...e the submenu 12 2 12 2 12 2 12 2 Alarm Alarm Alarm Alarm off timeout off timeout off timeout off timeout Enter the time span for the advance warning between crossing an alarm threshold and turning of...

Page 27: ...this setting to configure the desired speed of the generic rpm signal Range of adjustment 400 to 5000 rpm 12 8 12 8 12 8 12 8 Back Back Back Back Leaves the submenu and returns to Settings 13 Menu 13...

Page 28: ...D and allows the setting of a constant brightness The entered value is represented by a graphical bar If the brightness of the LED was regulated temperature dependent this call deactivates the tempera...

Page 29: ...n Time On Time On Time 2 2 2 2 Enter a second time as described in 14 2 Turn On Time 1 14 5 14 5 14 5 14 5 On On On On Time Time Time Time 2 2 2 2 Enter a second time as described in 14 3 On Time 1 14...

Page 30: ...he aquaduct can be monitored Furthermore single spots or areas of interest can also be monitored for instance by using two additional temperature sensors in the water supply and outlet lines of the CP...

Page 31: ...po wer measurement 2 This for instance could be the supply line of a wa ter cooler or the return line of the aquaduct 15 4 15 4 15 4 15 4 Measurement Measurement Measurement Measurement 2 Sensor 2 2...

Page 32: ...ation process by selecting this menu entry To perform the fill level analysis the pump will temporarily be set to a low reference speed and after completion be reset to its original speed 16 3 16 3 16...

Page 33: ...test operation while maintaining the full cooling capacity of the aquaduct if needed Set the following values for Sensor 1 Water out Target temperature 40 C Set the following values for Fan 1 to Fan 3...

Page 34: ...3 Emergency shutdown of the Emergency shutdown of the Emergency shutdown of the Emergency shutdown of the PC PC PC PC on temperature alarm on temperature alarm on temperature alarm on temperature alar...

Page 35: ...to disrupt the ATX control line Using the relay to disrupt the ATX control line If the relay output of the aquaduct is integrated into the ATX control line of the PSU standby power supply must be conn...

Page 36: ...ry knob By doing this the start process is ex tended and normal operation is temporarily suspended After the last movement of the knob it will take a moment before the operation starts 20 20 20 20 Tro...

Reviews: