Settings
7.1 Spreader disc, lateral distribution, spreader vanes
The spreader discs always run from the inside outwards. Left clockwise, right
anticlockwise. Be aware that the spreader vanes on the left scatter plate are
arranged differently to those on the right scatter plate. This installation of the
spreader vanes is tested via a lateral distribution test. If the spreader vanes are set in
this way, you obtain as even a scatter distribution and lateral distribution as possible
for all seed types.
7.2 Deflector / Guide plates
The guide plates, which are supplied as standard, are
attached to the ZS 200 M3 with the bolts provided for
this purpose. They prevent the carrier vehicle from being
pelted with scatter material.
Fig.: 11
Fig.: 12