26
Quality for Professionals
9
Controller messages
9.1 Fault(s)
Error messages have been provided to monitor the correct operation of the
implement and to inform the user if it can no longer be operated properly.
CAUTION: If the battery is charged by a charger which is in the "Start" operating
mode, this may result in voltage peaks! These can damage the control module's
electrical system if the control module is also connected when charging the battery!
Display
Cause
Solution
Supply voltage too low, too
high or voltage fluctuations
are too severe.
Check the on-board
electronics and the
battery.
Displayed if cables are not
connected or if cabling is
faulty.
Check the cabling and
connectors!
Displayed if the left
spreader disc (as seen
from the front = spreading
side of the device) cannot
turn or is under too heavy a
load.
If this message
appears on the
display, you must
switch off the device
and check whether
the spreader disc is
mechanically jammed.
Check the control
module for
overheating.
Displayed if the right
spreader disc (as seen
from the front = spreading
side of the device) cannot
turn or is under too heavy a
load.
If this message
appears on the
display, you must
switch off the device
and check whether
the spreader disc is
mechanically jammed.
Check the control
module for
overheating.
Displayed if the metering
slide valve cannot open or
close (as seen from the
front = spreading side of
the device).
If this message
appears on the
display, you must
switch off the device
and check whether
solids or similar
material are
preventing the
metering slide valve
from opening or
closing.
Supply voltage
Supply voltage
Supply voltage
Supply voltage
not OK!
not OK!
not OK!
not OK!
Motor not connected!
Motor 1
overloaded!
Motor 2
overloaded!
Slide valve
Slide valve
Slide valve
Slide valve
fault!
fault!
fault!
fault!