34
Step Description
1.1
5.2 Control Box: Pull out the power supply plug from the Control Box
and
For the electric fan PLUS, also pull out the power supply plug for the motor modules from the
seeder.
1.2
ISOBUS: Disconnect the plug from the tractor socket.
7.2
EMPTYING THE SEED HOPPER
Purpose
Before cleaning or decommissioning, the seed remaining in the seeder must be removed from the seed
hopper.
Requirements
The following requirement must be fulfilled for this work step:
The implement is disconnected from the power source, see
Disconnecting the seed drill from the power
source
on page 33 for more information.
Required components, tools and materials
For this work step, the following components, tools and materials are required:
None
Procedure
This is how to empty the seed hopper:
Step Description
Explanation
1
Loosen the hexagonal bolt (2) on the calibration
slide (1).
NOTE: The bolts are connected to the calibration
slide with the locking rings.
2
Take the calibration slide out of the anchoring and
turn it by 180°.
3
Attach the rotated calibration slide back onto the
seeder.
4
Start the emptying program of the control box, refer
to the control box operating manual for more
information.
7.3
CLEANING THE SEED DRILL
Purpose
The seed drill must be cleaned inside and out on a regular basis to ensure long-term proper functioning.
If not cleaned properly, germs can form inside the seed drill due to seed residues.
Requirements
The following requirements must be fulfilled for this work step:
The implement is disconnected from the power source, see
Disconnecting the seed drill from the power
source
on page 33 for more information.
Summary of Contents for PS 120 M1
Page 39: ...39 9 2 2 PS WITH ISOBUS Electric fan Hydraulic fan...