background image

 

ORIGINAL OPERATING MANUAL

 

           
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Version: 1.1 EN   /   Status: 09/2019   /   Item no.: 00601-3-951 

 

  Operating manual LF 600 M1 

 

Please read carefully before initial operation! 

 
 

 

 

Summary of Contents for LF 600 M1

Page 1: ...ORIGINAL OPERATING MANUAL Version 1 1 EN Status 09 2019 Item no 00601 3 951 Operating manual LF 600 M1 Please read carefully before initial operation...

Page 2: ...on the soil tillage implement 16 4 3 Connecting the hoses 17 5 Control box 19 5 1 Items included and connection 19 5 2 Basic settings 19 5 3 Main display 19 5 4 Settings 19 5 4 1 Spread rate l ha 20 5...

Page 3: ...e power source 29 8 2 Emptying residual quantities 29 8 3 Cleaning the Liquid Fertilizer 30 8 4 Repairs and service 31 9 Decommissioning storage and disposal 31 9 1 Decommissioning the Liquid Fertiliz...

Page 4: ...ng personnel Maintenance and repair personnel Parts of the document that must absolutely be read To prevent injuries and damage to the implement it is absolutely necessary to have read and understood...

Page 5: ...eaning 1 3 Service Service Please contact our service address in the following cases If you still have questions regarding the handling of the Liquid Fertilizer despite the information provided in thi...

Page 6: ...42 EC Machinery Directive 2014 30 EU EMC Directive Applied standards The following standards were applied EN 14982 Agricultural and forestry machinery Electromagnetic compatibility EN 15811 Agricultur...

Page 7: ...resh water tank For washing hands To flush the pump hoses and nozzles 4 Steel rack Hooking on and connecting implement components 5 Parking legs Ensure stability when the implement is not being used 6...

Page 8: ...The operator sets the implement up for operation and fills the fertilizer tank with liquid fertilizer 2 The operator activates the Liquid Fertilizer using the controls Result The pump rotates The flow...

Page 9: ...ersion Size Value LF 600 M1 Max tank content 600 l Weight 120 kg Dimensions H W D in cm 130 x 145 x 80 Electrical data Values for the pump Size Value Supply voltage 12 V Supply current 25 A Power cons...

Page 10: ...ting to your work completely You must understand these contents Always keep the operating manual close to the implement for reference purposes There is a container for this installed on the Liquid Fer...

Page 11: ...ral safety related and occupational health regulations must also be observed The manufacturer is not liable for any damage resulting from unauthorised modifications and the use of components and auxil...

Page 12: ...Chemical resistant overalls Waterproof footwear Breathing protection Safety glasses Mask Skin protection product 3 6 Safety devices Meaning of the safety devices The Liquid Fertilizer has safety devic...

Page 13: ...APV Technische Produkte GmbH Original operating manual LF 600 M1 Page 13 Overview This figure shows the position of the warning signs Figure 4 Position of the warning signs...

Page 14: ...o be processed Hazard due to contact with harmful substances caused by improper use of the clear water from the hand wash tank This hazard can cause severe injuries possibly even death Never use the c...

Page 15: ...the danger occur Countermeasure Danger due to defective implement parts When operating the implement Before operating the implement always check for fractures cracks chafe marks leaks loose bolts vib...

Page 16: ...ng requirement must be fulfilled for this work step The implement is disconnected from the power source see Disconnecting the Liquid Fertilizer from the power source on page 29 for more information Re...

Page 17: ...illustration 1 Distribute the nozzles evenly across the entire working width or on the seeding units of the implement 2 Fasten the nozzle holder plug connector on the implement 3 Connect the hoses to...

Page 18: ...ug connections on the distributor up to the end stop and pull lightly to make sure they are firmly attached 3 At the other end the hoses are fastened to the nozzle holders using plug connectors Betwee...

Page 19: ...s the implement type it remains stored If you should want to use the same control box to operate other implement series you can change the setting again in the Programming menu as described above 5 3...

Page 20: ...default value If contrary to expectations the actual spread rate should consistently deviate from the target spread rate corrections can be made by adjusting this value For example if the spread rate...

Page 21: ...measured and the system readjusted If the pump is not able to reach or maintain the desired spread rate a warning is issued through a corresponding error message If this should be the case the nozzle...

Page 22: ...point 2 A calibration test does not need to be performed as the pump is regulated by a flow sensor 3 The pulses for the flow sensor 2 5 50 l min must be set at 400 pulses l on the control box Calcula...

Page 23: ...then be added or deducted from the pulses litre 6 3 Selecting the right nozzles Purpose Fertilising results are significantly improved by selecting the right nozzle which is suitable for the spread r...

Page 24: ...tion 1 Push back the blue stop on the plug connector 2 Remove the nozzle 3 Push the new nozzle into the plug connector The nozzle engages automatically 4 Check that the nozzle is firmly seated by pull...

Page 25: ...he lid 3 clockwise 6 6 Switching between the fertilizer tank and the fresh water tank By switching over the ball valve the fertilizer tank or the fresh water tank H2O can be activated During operation...

Page 26: ...tilizer in it To do so the second ball valve must be set to the H2O function fresh water 6 8 Filter units Purpose The filters prevent unintentional soiling and damage to the pump and nozzles Requireme...

Page 27: ...nscrew the union nut 3 Pull out the filter cup by jiggling slightly to the right and left 4 Pull out the filter insert and clean with water 5 Check the O rings for damage 6 Reassemble in reverse order...

Page 28: ...mp is not sucking in Blockage on the suction side suction filter suction hose Eliminate the blockage The pump is sucking in air Check the hose connection on the suction hose for leaks The pump has no...

Page 29: ...lled for this work step None Required components tools and materials For this work step the following components tools and materials are required None Overview No Description Illustration 1 Implement...

Page 30: ...e implement must be cleaned inside and out on a regular basis to ensure long term proper functioning If not cleaned properly clumps can form inside the Liquid Fertilizer due to crystallisation Require...

Page 31: ...ely remove all liquid fertilizer from the implement 2 Rinse out the inside of the fertilizer tank with water see Cleaning the Liquid Fertilizer on page 30 for more information 3 Drain the remaining li...

Page 32: ...or the implement structure or if the cable cannot be routed practically this 2 m extension cable can be ordered as an accessory Items included 1 cable extension Order number 00410 2 148 Cable extensi...

Page 33: ...s This is how customer proximity of the development department creates a leading edge for you and APV Tell us about the positive and negative experiences you have had with the implement Share your sug...

Page 34: ...sor DS 1 4 mm blue 2 5 mm red 0 34 mm brown 2 4 mm brown 3 2 5 mm blue 2 5 mm black 4 0 75 mm grey 0 34 mm blue 0 34 mm black 5 0 75 mm brown 6 0 75 mm black 0 34 mm white Stripping length 10 mm Figur...

Page 35: ...Flow sensor 34 Forward speed 20 Fresh water 25 General 4 Grooves 23 Hose cutter 17 Hose roll 17 Identification 5 Implement cable 34 Implement layout 7 Installation and commissioning 16 Installing noz...

Page 36: ...2913 8002 Web www apv at Company details APV Technische Produkte GmbH Managing Director Ing J rgen Sch ls Dallein 15 3753 H tzelsdorf Austria marketing apv at www apv at VAT ID no ATU 5067 1107 Photo...

Reviews: