27
-
PTR-24
CONTROL UNIT
English
Programmable parameters
4.3
DISPLAY FUNCTION
VALUES
DEFAULT
Basic menu
(default setting shown to the right of the dot)
LO
Logic: 0 = Automatic; 1 = Semi-automatic Open/Close; 2 = Park;
3 = Semi-automatic 1; 4 = Semi-automatic 2; 5 = Manned; 6 = Timer
0 ÷ 6
0
(automatic)
PA
Pause time (0”- 60”) (1 step =1”)
0 ÷ 60
25
En
.
Force (thrust force on obstacle)
0 ÷ 5
0
SO
.
Speed on OPENING stroke
50 ÷ 80
70
SC
.
Speed on CLOSING stroke
50 ÷ 80
70
SP
.
SPECIAL logic: 0 = nol; 1 = yes;
0 ÷ 1
0
(no)
CM
.
Change hand con
fi
guration; 0= RH ; 1= LH
0
÷ 1
0
(Right-hand)
CP
.
Barrier class (beam length in metres): 0=2.0 ÷ 2.5 ; 1=3 ; 2=3.5 ; 3=4 ; 4=4.5
0 ÷ 4
0
(2.0 ÷ 2.5m)
PSET
Restore factory settings (default)
RED button to con
fi
rm
PRoF
To enter the programming mode
RED button to con
fi
rm
Advanced menu
(the 3rd and 4th digits indicate the default value)
A1
Pre-slowing start on opening stroke (as % of total travel)
01 ÷ 50
20
(%)
A2
Pre-slowing start on closing stroke (as % of total travel)
01 ÷ 50
20
(%)
A3
Pre-slowing speed on opening stroke
30 ÷ 50
30
A4
Pre-slowing speed on closing stroke
30 ÷ 50
30
A5
Pre-
fl
ashing on opening stroke
1 ÷ 5
3
A6
Pre-
fl
ashing on closing stroke
1 ÷ 5
3
A9
MASTER/SLAVE 0=none; 1= MASTER card ; 2= SLAVE card
0
÷
2
0
(Single barrier)
AA
START in pause (AUTOMATIC LOGIC); 0 = No effect ; 1 = Reloads the
pause time ; 2 = Stop the barrier in the open position.
0
÷
2
1
Ab
Closing when the photocell is no longer covered occurs:
1= immediately if the pause time has elapsed
2 = after 10 seconds
03 = after a complete new period of pause time (reloads the pause time)
1
÷
3
3
(reloads the
pause time)
Ad
Obstacle recognition on closing stroke; 0 = REOPEN (in the AUTOMATIC
mode, recloses after the pause) after 3 attempts wit reversing will remain open; 1
= REOPEN and stops in the open position.
0
÷
1
0
AE
Safety device during opening: (0 = safety edge; 1 = photocell)
0
÷
1
1
AF
Operation in emergency mode with batteries following a power supply failure
(indicated by rapid
fl
ashing)
00 = Runs 3 cycles and then remains closed
01 = Runs 3 cycles and then stops open
02 = Opens and stays open (safety functioning)
0
÷
2
0
LA
Tooled beam lighting programmable Output: (0 = 12V; 1 = 24V)
0
÷
1
0
tF
Closing photocell operational check (0 = disabled; 1 = enabled)
Carried out
before each movement (with exception of ER-REF); in the event of any fault
ER01
0
÷
1
0
AL
.
t
Total cycle counter, cannot be modi
fi
ed (increases by 1 ever 100 cycles)
0000
÷
9999
-
AL
.
P
Partial cycle counter (1 = 10 cycles) (reset using
AL
.
S
or
AL
.
r
)
0000
÷
9999
0000
AL
.
S
Sets the maintenance cycle on the partial cycle counter (1 = 10 cycles) in minimum
steps of 100 cycles. Each setting operation resets the
AL
.
P
counter.
0000
÷
9999
-
AL
.
r
Resets the
AL
.
P
counter
RED button to con
fi
rm
rn
.
Cancels a remote control whose address you know
(see Saving remote controls)
0
÷
99
00
r
.
tr
Cancels all the remote controls
(see Saving remote controls)
RED button to con
fi
rm
UPLd
Saves to an Optional external Memory Module the remote controls of the control unit
RED button to con
fi
rm
dnLd
Saves to the control unit the remote controls of the Optional external Memory Module
RED button to con
fi
rm
Parameters RESET
4.4
If you want to return all the programmed parameters to their default settings, you should
RESET
the unit as follows:
• Start BASIC programming. Scroll through the parameters and select
PSET
. Con
fi
rm this selection by pressing the
RED
button for 3 seconds.
Ö
The display will show the
fl
ashing
def
message while the default settings are restored and will
then display the message
LO
.
0
.
• To leave this function and continue with programming, press the
YELLOW
button.
Red
To con
fi
rm
Blue
To select
Yellow
To exit
IMPORTANT: