26
-
PTR-24
CONTROL UNIT
English
Ö
Ö
Ö
ProF
A1
Ö
Ö
Ö
A3
A2
00
.
ESC
ESC
Ö
A4
00
01
Ö
ESC
PROGRAMMING
4.
IMPORTANT! The barrier must be stopped and closed before you can start programming.
In order to save your settings you must complete and confi rm your settings and then leave the programming function. The display will
switch off. If the power supply fails for any reason during programming, all the modifi cations you have made will be lost.
IMPORTANT: All input signals will be ignored during programming.
Note: If the
MAN
message appears and fl ashes for 3 seconds when you enter the programming mode, this indicates
that you must complete the scheduled maintenance before proceeding.
BASIC programming
4.1
See the
fi
gure below.
ADVANCED programming
4.2
Complete steps 1 and 2 of Basic programming and then proceed with Advanced programming as shown in the
fi
gure below.
Ö
Ö
Ö
Ö
PROC
LO
.
0
Ö
Ö
O
.
Ö
2
2
.
ESC
ESC
Ö
YELLOW
YELLOW
Press and hold
the
RED
button
until “
PROC
” is
shown on the
display.
R e l e a s e t h e
button
Ö
the
f i r s t l e t t e r s
identifying the
programmable
parameters are
displayed.
Press the
BLUE
button to scroll
t h r o u g h t h e
programmable
parameters.
Press the
RED
b u t t o n w h e n
a parameter is
shown to display
the current setting
(marked by the
dot).
Press the
YELLOW
button to exit
and return to normal functioning:
the displays are switched OFF.
Press the
BLUE
but-
ton to scroll
t h r o u g h
the values
a v a i l a b l e
for the pa-
rameter.
If you decide not to make any modi
fi
cations,
press the
yellow
button
Ö
to display the
parameters again (step
o
).
RED
RED
RED
RED
BLUE
BLUE
o
n
p
q
r
s
Press and hold the
RED
button for 3 seconds to
select the value required
Ö
3 flashes confirm
that the new setting has
been saved. Release the
RED
button and press
the
YELLOW
button to
show the next parameter.
P r e s s t h e
BLUE
button to
scroll through
the parameters
until “
PRoF
” is
shown on the
display.
p
Press the
RED
but-
ton to access ad-
vanced program-
ming and show the
parameters.
q
P r e s s t h e
BLUE
button to
scroll through
the advanced
parameters.
r
RED
s
BLUE
t
RED
u
v
BLUE
Press the
YELLOW
button
Ö
to display the
next programmable
parameter. Program
P r e s s t h e
RED
button when the
parameter to be
modi
fi
ed is shown
and the value set is
shown (highlighted
by the dot).
Press the
RED
button
when the value required
is shown to make modi-
fi
cations
Ö
3
fl
ashes con-
fi
rm that the value has
been saved. Release
the
RED
button.
P r e s s t h e
BLUE
button
and scroll
through the
values avail-
able for the
parameter.
YELLOW
Press the
YELLOW
button to exit
and return to normal function-
ing: the displays are switched
OFF.
this parameter starting from step
r
or exit advanced
programming by pressing the
YELLOW
button repeatedly
until the displays are switched OFF.
YELLOW
YELLOW
BLUE
RED
Press the
YELLOW
button
to return to step
q
.