WIRING

 WARNING

120 volts may cause serious injury from electrical shock. Sudden operation 
may cause serious injury from moving parts. Leave power disconnected 
until installation is complete.

Follow these steps for all system connections. Wiring will vary depending on 
equipment. 

Wiring of the zone panel must comply with applicable codes, ordinances and 
regulations.

•  Use only 18 or 20 gauge solid (

non-stranded

) wire.

•  Strip off 7/16" of insulation from the wire.

•  Push wire into the terminal of the zone panel. 

•  To release the wire, press down on the top of the terminal and pull the wire out. 

•  The zone panel supports multiple options to route and anchor wires to the 

housing. See 

FIGURE 6

.

WIRE TIE MOUNTS

90-2073

FIGURE 6 

– WIRE TIE MOUNTS

6

B2206668C 61001213 AA 6202-6203 Zoned Comfort Control Install ENG-wrf.indd   6

6/14/18   3:28 PM

Summary of Contents for Zoned Comfort Control 6202

Page 1: ...READ AND SAVE THESE INSTRUCTIONS Model 6203 6202 Zoned Comfort Control Safety Installation Instructions B2206668C 61001213 AA 6202 6203 Zoned Comfort Control Install ENG wrf indd 1 6 14 18 3 28 PM...

Page 2: ...cooling system is properly sized and balanced 5 Insufficient air flow or excessive temperatures through the heating and cooling system could result in equipment damage Refer to the manufacturer s rec...

Page 3: ...IGURE 1 8 63 219 9 66 245 1 86 47 ZONE CONTROL 90 2108 FIGURE 1 ZONE PANEL DIMENSIONS IN INCHES mm APPLICATION ACCESSORIES APPLICATION The Model 6203 and 6202 Zone Panels are for conventional heat coo...

Page 4: ...12 COOLING Green Cooling is active Flashing DAT low temperature limit reached 13 FAN Green Fan output is active 14 ZONE 1 Green Damper is open Red Damper is closed 15 ZONE 2 Green Damper is open Red D...

Page 5: ...HVAC equipment Locate the panel on an interior wall stud or return duct See FIGURE 5 2 Locate the Discharge Air Temperature DAT in the supply trunk downstream of the heat exchanger and cooling coils...

Page 6: ...ly with applicable codes ordinances and regulations Use only 18 or 20 gauge solid non stranded wire Strip off 7 16 of insulation from the wire Push wire into the terminal of the zone panel To release...

Page 7: ...one panel and thermostats Example If you have a 3 zone system and there are two dampers per zone then the total number of dampers that could be energized at one time is 6 2 4 dampers 4 dampers x 10VA...

Page 8: ...ed damper For power open and power close dampers this terminal is used to power open the damper NO This terminal is used to power close a normally open damper For power open and power close dampers th...

Page 9: ...ermostat W Heating Y Cooling G Fan NOTE Heat cool thermostats must be used for all zones FURNACE AND A C HVAC TERMINAL DEFINITIONS Y1 First stage cooling W1 First stage heating G Fan BOILER AND A C HV...

Page 10: ...to the zone panel for heating the zone panel will initiate a heating call to the equipment and close the damper for all zones that are not calling for heat Following a 2 minute minimum on time the hea...

Page 11: ...OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECTS S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATI...

Page 12: ...1467 Madison WI 53701 1467 800 334 6011 F 608 257 4357 2018 Aprilaire Division of Research Products Corporation 61001213 B2206668C 5 18 B2206668C 61001213 AA 6202 6203 Zoned Comfort Control Install EN...

Reviews: