MODEL 8052 TEMP SENSOR
90-2087
FIGURE 10
– DISCHARGE AIR TEMPERATURE SENSOR
DISCHARGE AIR TEMPERATURE SENSOR (INCLUDED)
• Wire the discharge air temperature sensor
Model 8052 to the “DAT” terminals as
shown. See
FIGURE 10
.
• Maximum distance of the sensor from the
zone panel is 300 feet.
• Do not wire along 120VAC lines.
• Refer to
FIGURE 5
on page 5 for the proper
mounting location of the discharge air
temperature sensor.
THERMOSTAT TERMINAL DEFINITIONS
R
– 24VAC power to thermostat
C
– 24VAC power to thermostat
W
– Heating
Y
– Cooling
G
– Fan
NOTE:
Heat/cool thermostats must be used for all zones.
FURNACE AND A/C
HVAC TERMINAL DEFINITIONS
Y1
– First stage cooling
W1
– First stage heating
G
– Fan
BOILER AND A/C
HVAC TERMINAL DEFINITIONS
Y1
– First stage cooling
W1
– First stage boiler heat
G
– Fan
JUMPER
R
W1
G
Y1
FURNACE AND A/C
RC
W
Y
G
RH
HV
AC
Y1
G
R
BOILER AND A/C
R
C
W
BOILER
INDOOR AIR
HANDLER
AND A/C
RC
W
Y
G
RH
HV
AC
90-2115
90-2114
FIGURE 11
– FURNACE AND A/C
FIGURE 12
– BOILER AND A/C
HVAC TERMINAL DEFINITIONS
RH
– 24VAC from heating equipment
RC
– 24VAC from cooling equipment
W
– Heating
Y
– Cooling
G
– Fan