SPECIFICATIONS
INPUT RATINGS
Voltage:
18-30VAC 50/60 Hz
MAXIMUM CURRENT
Damper output per zone (fused):
18VA at 158°F, 30VA at 90°F
Zone panel and thermostats (fused):
18VA at 158°F, 30VA at 90°F
Zone panel consumption:
4VA max
Note:
Use 18 or 20 AWG solid (
non-stranded
) wire
ENVIRONMENT
Temperature (operating):
32°F – 158°F
Temperature (shipping):
-40°F – 180°F
Humidity:
5% – 90%, non-condensing
DIMENSIONS
See
FIGURE 1
.
8.63 (219)
9.66 (245)
1.86 (47)
ZONE CONTROL
90-2108
FIGURE 1
– ZONE PANEL DIMENSIONS IN INCHES (mm)
APPLICATION & ACCESSORIES
APPLICATION
The Model 6203 and 6202 Zone Panels are for conventional heat/cool
applications. The Model 6203 is for 3-zone installations and the 6202 is for
2-zone installations. The features include:
• 1 heating and 1 cooling stage
• Equipment protection
• Vacation mode – Zone 1 thermostat controls all zones
ACCESSORIES
•
Discharge Air Temperature Sensor (DAT):
Model 8052 (included)
3