In presence/absence experiments, wells that contain IPC blocking agent instead of
sample in the PCR reaction. No amplification should occur in negative control-
blocked IPC wells because the reaction contains no sample and amplification of the
IPC is blocked. Previously called no amplification control (NAC).
In presence/absence experiments, wells that contain IPC template and buffer or water
instead of sample. Only the IPC template should amplify in negative control-IPC
wells because the reaction contains no sample. Previously called IPC+.
See “negative control (NC)“ on page 187.
Molecules that are attached to the 3′ end of probes. When the probe is intact, the
nonfluorescent quencher (NFQ) prevents the reporter dye from emitting fluorescence
signal. Because the NFQ does not fluoresce, it produces lower background signals,
resulting in improved precision in quantification. The minor groove binder (MGB)
increases the melting temperature (T
m
) of the probe without increasing its length,
allowing for the design of shorter probes.
Type of calibration in which the software collects data from the normalization
standards, then stores it in a normalization calibration file.
Either the C
t
Avg. of the target gene minus the C
t
Avg. of the endogenous control
(Comparative C
t
experiments), or the Q Avg. of the target divided by the Q Avg. of
the endogenous control (Relative Standard Curve experiments).
The relative standard curve equivalent of the ΔC
t
mean value found in Comparative
C
t
experiments (computed as the geometric mean).
The relative standard curve equivalent of the ΔC
t
SE value found in Comparative C
t
experiments (computed as the geometric standard error of the mean).
Fluorescence signal from the reporter dye normalized to the fluorescence signal of the
passive reference dye (usually ROX
™
dye on Thermo Fisher Scientific instruments).
A measurement (such as a C
t
) that deviates significantly from the measurement of the
other replicates for that same sample.
A dye that produces fluorescence signal independent of PCR amplification, and that is
added to each reaction at a constant concentration. Because the passive reference
signal should be consistent across all wells, it is used to normalize the reporter dye
signal to account for non-PCR related fluorescence fluctuations caused by minor well-
to-well differences in volume. Normalization to the passive reference signal generally
results in data with noticeably high precision among technical replicates.
An illustration of the grid of wells and assigned content in the plate or array card. The
number of rows and columns in the grid depends on the sample block that you use.
negative control-
blocked IPC wells
negative control-
IPC wells
no template
control (NTC)
nonfluorescent
quencher-minor
groove binder
(NFQ-MGB)
normalization
calibration
normalized
quantity
normalized
quantity mean
normalized
quantity SE
normalized
reporter (R
n
)
outlier
passive reference
plate layout