52
EN
-
the inside of the bowl and the product unloading duct
: disassemble the gate valve tap as
explained previously, wash the inside of the bowl thoroughly, even with detergents or cleaning solutions
if necessary, as long as they are suitable for surfaces in AISI 304 stainless steel and, in any case,
following the corresponding safety datasheets. Rinse the inside of the bowl well with a gentle stream of
potable running water (be sure to remove any traces of detergent or cleaning solution that may have
been used) and let all the liquid drain out of the product unloading pipe. Run a 50 mm diameter medium
bristle brush through the pipe. Make sure all the parts are completely dry, then reassemble the
previously described gate valve tap.
WARNING! Damaged guards must be replaced immediately for the operator’s safety.
-
mobile guard with micro-switch on the bowl and parts under the head
(Fig. 6); opening the guard
automatically activates the safety micro-switch; wash the guard in AR with water, taking care to
thoroughly clean all the grooves (any detergents or cleaning solutions must be suitable for AR), then
rinse it with clean potable water. Use a damp cloth or, if necessary, clean potable water no warmer than
30°C to wipe down the plastic cover (do not use detergents or cleaning solutions that could be harsh on
plastic and ruin it), rinse it well; make sure all the parts are completely dry; use a damp cloth to wipe
down all the parts and surfaces under the head from where the accessory rotation shaft emerges.
Do not spray water or use compressed air
, as water compromises machine operation and
compressed air, creating dust, compromises the health of the people involved in the operating activities.
Only if truly necessary and, in any case, only after having put on a half mask respirator and protective
glasses, use short puffs of compressed air to remove stubborn residue and dust. Use an aspirator with a
narrow crevice tool to remove dust.
WARNING
Scattered flour and/or that has built up on structures and equipment must be cleaned as frequently as
possible, even several times during the same operating session as flour is a potential source of
explosions, being a finely ground organic dust.
GUARD
IN AR
COVER
IN PLASTIC
MICROSWIT
CH HINGE
Fig. 6